30 Barracuda 9 Installation Guide, Rev. B
Note. Signal ground on the power control board (PCB) and the
head and disc assembly (HDA) are connected together in
this drive and you cannot separate them. The equipment
in which you have mounted the drive is connected
directly to the HDA and PCB without electrically isolating
shock mounts. Maximizing the conductive contact area
between HDA ground and system ground may reduce
radiated emissions.
If you do not want the system chassis to be connected to
the HDA/PCB ground, you must provide a nonconductive
(electrically isolating) method of mounting the drive in the
host system. This may increase radiated emissions and
is the system designer’s responsibility.
Hinweis:
Die Signalerde auf der Stromregelungskarte (PCB) und
der Kopf- und Festplatteneinheit (HDA) sind in diesem
Laufwerk miteinander verbunden und können nicht
getrennt werden. Das Gerät, in das Sie das Laufwerk
eingebaut haben, ist ohne elektrisch isolierende
Stoßdämpfer direkt an die HDA und PCB angeschlossen.
Die elektromagnetische Strahlung kann reduziert wer-
den, indem Sie eine möglichst große leitende Kontak-
fläche zwischen der HDA-Erdung und der Systemerdung
vorsehen.
Wenn Sie das Systemgehäuse nicht an die HDA/PCB-
Erdung anschließen wollen, müssen Sie das Laufwerk
auf nichtleitende Weise (galvanisch isoliert) im Host-Sys-