Seagate ST32550N/ND Computer Monitor User Manual


 
N/ND drives
Other applicable jumper options
Several other jumper options are available as illustrated.
J2
J4
Remote LED 
connector*
J4
Pin 1
Pin 1
Reserved
GND (cathode)
POS (anode)
(front view of J4)
Pin 2
Enable parity check of 
SCSI bus (default).
Disable parity check.
J2
Pin 1
Pin 2
Reserved
Pin 1
Note to subsystem designers: In 
Europe, a red LED indicates an error 
or warning condition. For this reason, 
you may want to use a color other 
than red with this connection.
*
Parity Check option
Write protect = Off 
(enables writing – 
default)
Write protect = On 
(disables writing)
Write Protect option
Disable the Delay Motor
Start option (default).
Motor start delay equal 
to the SCSI ID multiplied 
by 10 seconds. For 
example, if the SCSI 
ID = 2, the drive starts 
in 20 seconds.
Delay Motor Start 
option (valid only if the 
Motor Start jumper is 
not connected)
Enable motor start. The 
drive waits for the Start 
Unit command from the 
host before starting the 
spindle motor.
Disable motor start 
(default). The drive 
starts according to the 
Delay Motor Start option.
Motor Start option
Figure 9. Additional jumper options
Barracuda 2LP Installation Guide, Rev. E 37