Seagate ST336605FC/FCV Computer Drive User Manual


 
Cheetah 73LP FC Product Manual, Rev. D 35
9.0 Interface requirements
This section partially describes the interface requirements as implemented on Cheetah 73LP FC drives. Addi-
tional information is provided in the
Fibre Channel Interface Manual
(part number 77767496).
9.1 FC-AL features
This section lists the Fibre Channel-specific features supported by Cheetah 73LP FC drives.
9.1.1 Fibre Channel link service frames
Table 3 lists the link services supported by Cheetah 73LP FC drives.
9.1.2 Fibre Channel task management functions
Table 4 lists the Fibre Channel SCSI Fibre Channel Protocol (FC SCSI FCP) task management functions sup-
ported.
9.1.3 Fibre Channel task management responses
Table 5 lists the FC SCSI FCP response codes returned for task management functions supported.
Table 3: Link services supported
Type of frame Link service
Basic link service frames Abort Sequence (ABTS)
Basic link service reply frames Basic_Accept (BA_ACC)
Basic_Reject (BA_RJT)
Extended link service frames N_Port Login (PLOGI)
Fabric Login (FLOGI)
Logout (LOGO)
Process Login (PRLI)
Process Logout (PRLO)
Read Link Status (RLS)
Fabric Address Notification (FAN)
Port Discovery (PDISC)
Address Discovery (ADISC)
Third-party Process Logout (TRPLO)
Extended link service reply frames Accept (ACC)
Link Service Reject (LS_RJT)
Fibre Channel Services Register FC-4 Types (RFT_ID)
Table 4: Fibre Channel SCSI FCP task management functions
Task name Supported
Ter minat e task No
Clear ACA Yes
Target reset Yes
Clear task set Yes
Abort task set Yes
Table 5: FC SCSI FCP response codes
Function name Response code
Function complete 00
Function not supported 04
Function reject 05