30
SV35 Series SATA Product Manual, Rev. B
4.3 Supported ATA commands
The following table lists Serial ATA standard commands that the drive supports. For a detailed description of
the ATA commands, refer to the Serial ATA: High Speed Serialized AT Attachment specification. See
“S.M.A.R.T. commands” on page 38.for details and subcommands used in the S.M.A.R.T. implementation.
Table 7: Supported ATA commands
Command name Command code (in hex)
Check Power Mode 98
H
or E5
H
Device Configuration Freeze Lock B1
H
/ C1
H
Device Configuration Identify B1
H
/ C2
H
Device Configuration Restore B1
H
/ C0
H
Device Configuration Set B1
H
/ C3
H
Device Reset 08
H
Download Microcode 92
H
Execute Device Diagnostics 90
H
Flush Cache E7
H
Flush Cache Extended EA
H
Format Track 50
H
Identify Device EC
H
Idle 97
H
or E3
H
Idle Immediate 95
H
or E1
H
Initialize Device Parameters 91
H
Read Buffer E4
H
Read DMA C8
H
Read DMA Extended 25
H
Read DMA Without Retries C9
H
Read Log Ext 2F
H
Read Multiple C4
H
Read Multiple Extended 29
H
Read Native Max Address F8
H
Read Native Max Address Extended 27
H