Seagate ST910021AS Computer Drive User Manual


 
Momentus 7200.1 SATA Product Manual, Rev. B
9
2.9.1.1 Typical current profiles
Figure 1. Typical 5V startup and operating current profile
2.9.2 Deferred spinup
Momentus 7200.1 SATA drives provide a deferred spinup feature which storage subsystem controllers can use
to sequence disc drive initialization. This is beneficial to systems which include multiple Serial ATA hard disc
drives because it allows subsystem controllers to stagger the spinup of each drive to accommodate available
power supply current. This feature does not impact time-to-ready in typical desktop systems.
To accommodate the deferred spinup of multiple disc drives in an enclosure, Momentus 7200.1 SATA disc
drives will spin up only after power is applied to the drive and after successful PHY (Physical layer) initializa-
tion. PHY initialization occurs after the PHY enters the DP7:DR_Ready state. This state is reached after a suc-
cessful exchange of Out-Of-Band (OOB) signals with a functional host-side Serial ATA port. In desktop
systems, SATA transceivers should initialize OOB as soon as power comes ready to guarantee the drive spins
up quickly. Seagate disc drives will not spin up without an operational host-side Serial ATA transceiver.
Additional details
Upon system power up, PHY communication is initiated with a COMRESET signal, which is generated by the
host-side transceiver. COMRESET is followed by a COMINIT signal generated by the disc drive transceiver.
COMRESET and COMINIT are followed by an exchange of COMWAKE signals and Align primitives. The disc
drive will spin up after the successful exchange of Align primitives cause the PHY to come ready.
For more details, refer to:
Section 6.8 of the Serial ATA 1.0 High-Speed Serialized AT Attachment specification
Section 6.2 of the Serial ATA II: Extensions to Serial ATA 1.0 specification
SATA 1.0 design guides
Note. These specifications and guides are available on the Serial ATA web site (www.serialata.org).