2.9.3 Conducted noise
Input noise ripple is measured at the host system power supply across an equivalent 15-ohm resistive load on
the +5 volt line.
Using 5-volt power, the drive is expected to operate with a maximum of 100 mV peak-to-peak square-wave
injected noise at up to 10 MHz.
Note. Equivalent resistance is calculated by dividing the nominal voltage by the typical RMS read/write
current.
2.9.4 Voltage tolerance
Voltage tolerance (including noise):
5V ± 5%
2.10 Environmental specifications
2.10.1 Ambient temperature
Ambient temperature is defined as the temperature of the environment immediately surrounding the drive.
Actual drive case temperature should not exceed 65°C (149°F) within the operating ambient conditions.
Above 1,000 feet (305 meters), the maximum temperature is derated linearly by 1°C every 1000 feet.
2.10.2 Temperature gradient
2.10.3 Humidity
2.10.3.1 Relative humidity
2.10.3.2 Wet bulb temperature
2.10.4 Altitude
Operating: 5° to 40°C (41° to 104°F)
Nonoperating: –40° to 70°C (–40° to 158°F)
Operating 20°C per hour (68°F per hour max), without condensation
Nonoperating 30°C per hour (86°F per hour max), without condensation
Operating 5% to 90% noncondensing (30% per hour max)
Nonoperating 5% to 95% noncondensing (30% per hour max)
Operating 30°C (86°F max)
Nonoperating 40°C (104°F max)
Operating –304.8 m to 3,048 m (–1,000 ft to 10,000+ ft)
Nonoperating –304.8 m to 12,192 m (–1,000 ft to 40,000+ ft)