4.1.1 ATA interface specifications
The Momentus 5400 FDE is consistent with the ATA Interface implementation of the Momentus 5400.2 prod-
ucts with the known exceptions listed within this section (Section 4.1.1 subordinate sections).
4.1.1.1 Legacy mode -- Multi-word DMA not supported
If multi-word DMA model is selected, the drive response is indeterminate, and the ATA bus will hang. Due to
this limitation, the drive will violate the DCO Set requirement in the ATA specification.
4.1.1.2 Legacy mode -- Interrupts disabled mode (polling) supports limited functionality
Interrupts disabled mode is entered upon setting of the nIEN bit to 1, in the Device Control Register as shown
in the ATA Specification.
Upon entry of this mode the drive will behave normally in the absence of issuance of the following user data
access commands, to the drive:
READ/WRITE BUFFER
READ/WRITE SECTOR
READ/WRITE SECTOR EXT
READ/WRITE MULTIPLE
READ/WRITE MULTIPLE EXT
READ/WRITE DMA
READ/WRITE DMA EXT
If any of the identified data access commands are issued to the drive, the drive will tri-state the data bus and
the retrieved data will be indeterminate. Additionally, the drive will return indeterminate values in the status reg-
ister.
Upon entry into the described state, the drive will remain in this state until you power cycle the drive.
If the nIEN bit is set to 1 and none of the identified data access commands are issued, the nIEN bit may be
returned to 0 and the drive will continue with normal operation in the Interrupts Enabled mode.
4.1.1.3 PIO Read -- Interrupts Enabled mode
In the Interrupts Enabled mode, the drive has limited support for the host to check the status register of the
drive while waiting for the data transfer interrupt.
If the host polls the status register, while waiting for interrupts and the drive has not yet posted the interrupt, the
drive will tri-state the data bus. This limitation is only an issue for any host that might choose to transfer the
data prior to the DRQ bit being set. For instance, any host that reads a status of 0x20 may, based on the drive
Busy bit and Error bit being cleared, choose to transfer the data, even though the DRQ bit is not set. This is not
recommended host behavior, and, if implemented, would result in undesirable results.
This limitation is not an issue for hosts that simply wait for the interrupt to be posted.
This is not believed to be an issue for hosts that check status but wait for the DRQ bit to be set.
Table 7: Interrupts Disabled mode nIEN bit
7 6 5 4 3 2 1 0
HOB r r r r SRST nIEN 0