SAFETY INSTRUCTIONS
WARNING: When using this device, always exercise basic safety precautions, including the following:
Read all instructions before installation or use.
Never connect this device to any electrical circuit with other than 12 or 24 volt Direct Current or exceed
the amperage draw listed below.
Never install the indicator panel in an atmosphere with potentially flammable or explosive vapors.
Never install the probe cap with float switches into a tank that contains anything other than fresh, gray or
black water.
CAUTION: Dropping or rough handling of float switches may result in damage.
PRODUCT FEATURES
Eliminates false reading from fouled probes.
Three float switches, four level indications for all tanks up to 22-inch (559mm) & 45-inch (114cm) in depth.
Deluxe panel complements bathroom decor and provides international symbology.
Installs in any rigid tank with optional 3-inch NPT mounting flange.
One model operates on 12 or 24 VDC.
Probe cap provides clean out for easy access to interior of tank.
Cap is available with or without 5/8" vent hose connection.
Optional shut-off relay plugs into back of circuit board to shut down toilet or water system when gray or
black water tank is full or when freshwater tank is empty.
Always one level light on to confirm that electrical power is applied.
Only one level light on at a time to eliminate confusion and save battery power.
CE and IMCI approved for electromagnetic compatibility.
The TankWatch 4 Level Monitor System is designed to permit remote sensing of liquid levels in wastewater, gray
water or potable fresh water tanks. The TankWatch 4 utilizes three micro-float switches, which activate a four-
light panel. One is fixed and activates a full light when the liquid is within approximately 2-inches of the top
inside surface of the tank. The other two float switches are mounted on adjustable stems and can be positioned
to within 2-inches of the bottom of the tank. The stems are semi-flexible and are designed to flex with the
sloshing of the tank contents. A simple procedure allows one adjustable stem to sense when the tank is empty
and the other adjustable stem to sense when the tank is 1/4 or 1/2 full, depending on the application.
MODELS AND ACCESSORIES
Safety Instructions . . . . . . . . . . . . . . . . . . . . . . .2
Product Features . . . . . . . . . . . . . . . . . . . . . . . .2
Models and Accessories . . . . . . . . . . . . . . . . . . .2
Dimensional Specifications . . . . . . . . . . . . . . . . .3
Product Specifications . . . . . . . . . . . . . . . . . . . . .3
Installation Instructions . . . . . . . . . . . . . . . . . 4 - 5
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . .6
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Manufacturer’s One-Year Limited Warranty . . . . .8
Control Panel Mounting Template
313600113
313600114
313600115
313600116
307230272
600341292
600342490
385318714
360600212
360600224
TankWatch
®
4 Panel and Cap with Vent, 22-inch Probes
TankWatch
®
4 Panel and Cap without Vent, 22-inch Probes
TankWatch
®
4 Panel and Cap with Vent, 45-inch Probes
TankWatch
®
4 Panel and Cap without Vent, 45-inch Probes
Universal Flange (3-inch NPT) with gasket and stainless steel hardware
Plug In Relay, 12VDC
Plug In Relay, 24VDC
“Do Not Flush” Panel
TankWatch
®
4 Panel with 12VDC Relay
TankWatch
®
4 Panel with 24VDC Relay
Part Number Description