3
CONNECTING CABLE ASSEMBLY4.
Determine whether you’ll be using the battery clamps (750 watt out-
put maximum) or accessory plug (120 watt output maximum).
Make sure that there is no device plugged into inverter before making con-4.1
nection.
Unscrew the positive (red) and negative (black) plastic connector knobs 4.2
from the studs on the back of the inverter.
Slip the red (positive) ring terminal of the 12V accessory plug over the red 4.3
(positive) stud. Screw on the connector knob and tighten securely. Repeat
the same process for the black ring terminal.
Accessory Plug: 4.4 Push the 12V accessory plug rmly into a 12V acces-
sory outlet.
Battery Clamps: Connect the red (positive) battery clamp to the posi-
tive (+) battery terminal. Connect the black (negative) battery clamp to
the negative (-) battery terminal, taking care to shield eyes, clothing and
hands from battery acid.
USING INVERTER5.
Determine the wattage of device being used. The Power inverter 750
must be used with devices drawing 750 watts or less when being
used with the Battery Clamps and 120 watts or less when using the
Accessory Plug.
Plug the device to be operated into either the AC outlet of the inverter or 5.1
USB connector. NOTE: If using more than one device, the total combined
wattage of both devices must not exceed 750 watts.
Press and hold5.2 the ON/OFF button to turn the inverter ON. The VOLT-
AGE IN indicator will glow and the digital display will show the DC input
voltage.
Turn the device ON. To show AC VOLTAGE OUT, press the ON/OFF 5.3
button once. Press the ON/OFF button once again to show total wattage
used by the device (POWER OUT). NOTE: If there is a short circuit or
power surge in the device, SC will display and an alarm will sound. Press
the ON/OFF button to turn off the alarm. If the SC displays after several
attempts, there is a short circuit or the device requires more surge power
than the inverter is capable of providing.
TO DISCONNECT THE INVERTER:5.4
Turn device OFF
Press and hold• the ON/OFF button to turn the inverter OFF
Unplug the device from inverter
If using the Accessory Plug, unplug inverter from 12V DC accessory