1 – 1
UX-258TH
FO-475TH
CHAPTER 1. GENERAL DESCRIPTION
[1] Specifications
Automatic dialing: Rapid Key Dialing: 10 numbers
Speed Dialing: 20 numbers
Fax paper: Initial starter roll (included with fax
machine): 10 m roll
Recommended replacement roll:
FO-40PR 50 m roll
Automatic document feeder: 10 sheets max.
Paper cutting method: Automatic cutter
Modem speed: 9600 bps with automatic fallback to
7200, 4800, or 2400 bps
Transmission time* : Approx. 15 seconds (Sharp special mode)
Display: 7 x 5 dots, 1 line by 16-digit display
Reception modes: TEL, FAX, TEL/FAX, ANS.
Resolution: Horizontal:
8 dots/mm
Vertical:
Standard: 3.85 lines/mm
Fine/Halftone: 7.7 lines/mm
Super fine: 15.4 lines/mm
Recording system: Thermal recording
Halftone (grayscale): 64 levels
Applicable telephone line: Public switched telephone network/PBX
Compatibility: ITU-T (CCITT) G3 mode
Configuration: Half-duplex, desktop transceiver
Compression scheme: MH, MR, Sharp special mode
Scanning method: Sheet-feeder CIS (Contact Image Sensor)
Effective recording width: 210 mm max.
Input document size: Automatic feeding:
Width 148 to 216 mm
Length 140 to 297 mm
Manual feeding:
Width 148 to 216 mm
Length 140 to 600 mm
Effective scanning width: 210 mm max.
Contrast control: Automatic/Dark selectable
Copy function: Standard
Telephone function: Standard
(cannot be used for incoming/outgoing
if power fails)
Power requirements: 220-240 V, 50 Hz
Operating temperature: 5 to 35°C
Humidity: Maximum: 85 %
Power consumption: Stand-by: 6.0 W
Maximum: 120 W
Dimensions: Width: 308 mm
Depth: 256 mm
Height: 138 mm
Weight: Approx. 2.6 kg
(without attachements)
* Based on ITU-T (CCITT) Test Chart #1 at standard resolution in Sharp
special mode, excluding time for protocol signals (i.e., ITU-T phase C
time only).
As a part of our policy of continuous improvement, SHARP reserves the right to make design and specification changes for procduct
improvement without prior notice. The performance specifications figures indicated are nominal values of production units. There may be some
deviation from these values in individual units.