Shure AXT900 Tablet Accessory User Manual


 
2
⑦ AC power cascade
Powers additional units.
⑧ Ethernet ports (2)
Connect to an Ethernet network to enable remote control and monitoring.
⑨ Network status LED (green)
Off = No network link
On = Network link active
Flashing = Network link active, flash rate corresponds to traffic volume.
⑩ Network speed LED (amber)
Off = 10 Mbps
On = 100 Mbps
⑪ Cooling fan vent
Clean fan screen as needed to maintain airflow.
⑫ Power switch
Powers the unit on and off.
Controls And Connectors
Charger System
SET
AXT 900
AXT900
Controls
1. Use the arrow keys to scroll to the desired menu.
2. Press the SET key to enter the selected menu item.
3. Use the arrow keys to change a menu parameter.
4. Press SET to save the setting.
Press and hold both arrow keys to enter or exit the Utility
menu.
SET
IP Mode:
Automatic
⑨ ⑧ ⑩
Charge Status LED
Each charger bay has an LED to indicate the status of the battery.
Red battery charging
Green charging complete
Off battery inserted incorrectly or battery depleted below
3.0 volts.
Amber charging stopped at reduced capacity (not less than
75% capacity) because the battery is too warm. To
reach 100% capacity, a battery must be cooled to be-
low 45°C.
① LCD screen
Displays battery status and menu settings
② Control keys
For navigating the LCD screen. Press and hold both arrow keys to enter or
exit the utility menu.
③ Charging module
Interchangeable modules for handheld and bodypack batteries.
④ Charge Status LED
Indicates battery charge status
⑤ Monitoring Selection LED
This white LED shows which battery is selected in the monitoring menu.
⑥ AC power in
Connect to AC mains with supplied power cable.