Smart Technologies SE240 Switch User Manual


 
Configuring the SMART Hub SE240 37
5. Select the Enable room control with RS-232 check box.
6. Press Apply All.
You’ve enabled the SMART Hub SE240’s room control mode through the serial interface.
The SMART Hub SE240’s serial interface settings aren’t configurable. Therefore, configure your
computer’s serial communication program, such as Microsoft® HyperTerminal, or your room
control system’s serial communication settings to the following values.
1. Turn on your communication program.
2. Configure your communication program as documented in the previous section.
3. Press Enter.
If your configuration is correct and the SMART Hub SE240 is in room control mode, the >
character appears.
4. Type ?, and then press Enter to see a list of available commands.
Enabling and Using Room Control Settings through TELNET
Instead of connecting the SMART Hub SE240 to room control through the serial interface, you can
connect through TELNET.
1. Connect the SMART Hub SE240 and the computer or room control system to the same
network.
For more information on connecting the SMART Hub SE240 to a network, see page 29.
2. Press Menu.
The Welcome Center appears.
3. Press Settings.
The Settings dialog box appears.
4. If a password is required to change the configuration settings, type the password in the box at
the bottom of the menu, and then press OK.
NOTE: For information on the configuration settings password, see page 20.
To configure your serial interface settings
Setting Value
Data rate 9600 bps
Data bits 8
Parity None
Stop bits 1
Flow control None
To verify that the serial interface is in room control mode
To connect the computer or room control system to the SMART Hub SE240
through TELNET