SMC Networks EX250-SEN1 Switch User Manual


 
10 11
Specifications
Sensor
input area
1 0
I/O mapping
Offset
(word)
Input data
MSB LSB MSB LSB
15 8 70
0
1
Input area mapping
15 14
L : Fixed to Low
Item Status Condition
SP Solenoid power supply status
0 No supply voltage
1 Supply voltage OK
DI Status of sensor power supply
0 Short circuit
1 Normal
Diagnostics (Status input area)
2
LLLL LLLLLLLLLL
Status input area
SP DI
8 7
13 12
11 10
9
26 5 4 3
17 16
31
30
24 23
29 28
27 26 25 1822 21 20 19
1 0
Offset
(word)
Output data
MSB LSB MSB LSB
15 8 70
0
1
Output area mapping
15
14
8 7
13 12
11 10 9 26 5 4 3
17 16
31 30
24 23
29 28
27 26 25 1822 21 20 19
Basic specifications
Rated voltage 24VDC
Range of power
supply voltage
Power supply for input and control : 24VDC 10%
Power supply for output : 24VDC+10%/-5%
Rated current Power supply for input and control : Max. 1.1A
Inside SI Unit : 0.1A
Input device :1A
Power supply for output : Max. 2A
Number of input/
output points
Input point : Max. 32/Output point : Max. 32 *
Higher-level bus
(
)
Protocol Ethernet (IEEE802.3)
Media 100BASE-TX
Communication
speed
10M/100Mbps (Automatic selection or manual setting)
Max. segment length 100m (328ft)
Max. transceiver number 2 (per segment)
Communication
method
Full duplex/Half duplex (automatic selection or manual
setting)
Fieldbus protocol EtherNet/IP™ Release1.0
I/O message
Input : Data length 6 byte, Instance 100.
Output : Data length 4 byte, Instance 150.
Port No.
44818 (0xAF12)
IP address setting range
192.168.0.1 to 192.168.0.14 (Setting by an internal switch)
Or optional setting by the DHCP server
Device information
Vendor ID : 7 (SMC Corp.)
Product type : 12 (communication adapter)
Product code : 107
Output type PNP output (-COM.)
* The maximum output point is 24 when the Power Block is connected.