Sierra Monitor Corporation 5301-10 Printer User Manual


 
The Sentry Printer Option aids in management of
your gas risk with the ability to print a variety of
complete reports.
Sentry's preformatted reports provide critical information
for analyzing gas exposure and evaluating system reliabil-
ity. Report selection criteria are user definable. These
reports:
Help user make better decisions during a gas leak
Provide history to analyze all exposure events
Substantiate due diligence in complying with regu-
lations
Confirm the reliability of the system.
With optional Sentry printer software, preformatted reports
can be printed via the RS232 port on the Sentry connector
panel. Output is either directly from one controller to a
printer or, via the Sentry Master and Subordinate network
system, from several controllers to one printer.
STATUS REPORT
Status Reports show a snapshot of the gas concen-
tration and alarms. The reporting interval is user pro-
grammable from 1 hour to 7 days. The first line indi-
cates the controller ID and date/time. The second
line indicates the sensor number and alarm condition
(“L” for low alarm and “H” for high alarm). The third
line indicates the current concentration and the fourth
line indicates the gas type.
SYSTEM REPORT
The System Report lists all the system parameters
including the software configuration of the system, cali-
bration configuration, printer configuration and configu-
ration for each module: on/off condition, calibration sta-
tus, relay latching configuration, alarm levels, module
type, the controller channel to which it is connected,
and calibration conditions and factors.
Sentry
Printer Option
Sierra Monitor Corp. 1991 Tarob Ct., Milpitas, CA 95035, USA, 408-262-6611, 800-727-4377, FAX: 408-262-9042
Web Site: http://www.sierramonitor.com E-Mail: sales@sierramonitor.com
© 2009 by Sierra Monitor Corporation
The Sentry Printer is a modern, high-speed, quiet, ultra
compact, state-of-the-art printer that can operate as either
a serial or parallel output printer.
This printer utilizes thermal paper
and thus no ink! It has minimal
moving parts, easy maintenance
with self-diagnostics, and easy
paper loading with a clamshell de-
sign. Standard power for the 5301-
10 is 12-24 VDC. An optional
power supply is available to en-
able an operator to use 120VAC
power..
Printer (5301-10)
5301-10 Serial/Parallel Compact Printer
SPL69207 120V Power Supply
SPL69205 Thermal Paper for Compact Printer
DIAGNOSTIC REPORT
The Diagnostic Report lists the critical voltage conditions
for each module and can be selected to print periodically
at intervals from 1 to 90 minutes.
--------------------------------
<STATUS REPORT>
ID:A STATUS = 01 HOUR 12/17 15:00
1 2 3 4 5 6 7 8
03 04 20.9 20.9 08 08 18 19
H2S COMB OXY OXY COMB COMB COMB COMB
---------------------------------
<STATUS REPORT>
ID:A STATUS = 01 HOUR 12/17 16:00
1L 2 3 4 5 6 7 8
03 04 20.9 20.9 08 09 08 08
H2S COMB OXY OXY COMB COMB COMB COMB
---------------------------------
<STATUS REPORT>
ID:A STATUS = 01 HOUR 12/17 17:00
1 2 3 4 5 6 7 8
13 04 20.9 20.9 08 09 22 19
H2S COMB OXY OXY COMB COMB COMB COMB
--------------------------------------
<STATUS REPORT>
ID:A STATUS = 01 HOUR 12/17 18:00
1H 2 3L 4 5 6 7L 8
23 04 19.5 20.9 08 06 40 19
H2S COMB OXY OXY COMB COMB COMB COMB
---------------------------------
<SYSTEM REPORT>
ID:A USER # = 1 12/17 15:08
M5000 VER:4.19
PN 8C
CALIBRATION CONFIGURATION:
LC: OFF CAL FREQ= 90 DAYS
H2S = 20 CAL DUE = 88 DAYS
COMB= 60 CAL DUE = 89 DAYS <SEL>
PRINTER CONFIGURATION:
PRINTER: ON STATUS = 07 DAYS HIST:YES
H2S : MIN. CONC. = 05 CHANGE = 03
COMB: MIN. CONC. = 08 CHANGE = 13
MODULE CONFIGURATION :
MODULE 1 IS ON H2S CHANNEL=1
LA= 10 NLATCH HA= 20 LATCH
FACTOR(S)= 100 150 200
MODULE 2 IS ON COMB CHANNEL 2