7. Because of this current sharing feature, you may plug in any combination of emitter models E1, VE1, E2, &
VE2 to the CB1 (up to a maximum of 8
individual emitters) to drive the desired number of devices.
NOTE 1: Be sure the PS1 Power Supply is plugged into an un-switched AC outlet.This maintains
the system in "standby" operation so that power-on commands can be sent to the controlled
equipment.
IMPORTANT NOTE:When using long lengths (more than 200 feet) of inter-room shielded cable, it
may be necessary to connect a 470 ohm 1/8 watt resistor between input (signal) and GND at the
IR input terminals of Sonance Connecting Blocks, Zone Controllers, etc. Refer to Fig. 3.The
resistor discharges the cable capacitance more quietly, allowing IR codes of high bit rates to
pass without data loss.
MAIN ROOM, EQUIPMENT CABINET, ETC.
GND
OUT
+12V
ROOM 3
+12VDC
GND
GND
SIGNAL
OUT
GND
+12V
ROOM 1
ROOM 2
3-Wire
Cable
3-Wire
Cable
Red
Stripe
Red
Stripe
OUT
GND
+12V
OUT
PWR
IR
RCVR
GND
OUT
+12V
7 Foot Quick
Connect Cable
ROOM 4
SMR1 Series
IR Receivers
MR1
Series
Micro IR Receivers
CR1
Connecting
Block
CR1
On-Cabinet
IR Receiver
+12V
OUTPUT
GND
WMR1
Wall Mount
IR Receiver
SMR1P
Surface Mount IR
Receiver w/Mini Plug
CAUTION:
See text, item 5.
WMR1
WALL MOUNT
IR RECEIVER
7 Foot 3-Conductor
Cable with Quick
Connect Stereo Mini Plug
(to other
controlled
devices)
See Item 4
PS1
Power
Supply
CB1
Connecting Block
120 VAC
(Unswitched; see NOTE 1)
EMITTERS
PWR
IR
RCVR
CB1
ONE ZONE
CONNECTING BLOCK
E1 Emitter
E1 Emitter
VE2 Dual
IR Emitter
VE1 IR
Emitter
Satellite Receiver
AV Receiver
DVD
Fig. 2 A Typical CB1 System
+12 VDC
GND
GND
SIGNAL
470 Ohm resistor
Shielded Cable
to remote room
Ground Shield as shown
CB1 Input
Terminal
Fig. 3: 470 Ohm Capacitance Discharge Resistor (for shielded cable longer than 200 feet.)