Sony 510A2WJ Computer Monitor User Manual


 
36 (GB)
Self-diagnosis Function
The unit has a self-diagnosis function.
This function displays the monitor’s condition with
the 1 indicator flashing and numbers on the
SERVICE CODE indicator on the left connector
panel. The numbers inform you of the monitor’s
current condition.
When the unit is working properly, only the dot at the
lower-right position on the SERVICE CODE indicator
flashes.
If the 1 indicator flashes, check the number and
contact your authorized Sony dealer.
1 Check the two-digit number on the SERVICE
CODE indicator.
The indicator shows one number, or multiple
numbers alternately in one second intervals.
2 Unplug the unit.
Inform your authorized Sony dealer of the
number.
Operating a Specific Monitor
With the Remote Commander
Using the supplied Remote Commander, you can
operate a specific monitor without affecting other
monitors that are installed at the same time.
1 Press ID MODE ON on the Remote Commander.
Monitor index numbers appear in white characters
on all the monitors. (Every monitor is allocated an
individual preset index number from 1 to 255.)
See “To change the index number” in the left-hand
column on the next page to change the index number.
ON
ID MODE
SET
OFF
INDEX No.117 . ..
Self-diagnosis Function / Operating a Specific Monitor With the Remote Commander
2 Input the index number of the monitor you want to
operate using the 0 – 9 buttons on the Remote
Commander.
The input number appears right next to the index
number of each monitor.
2
5
8
3
6
9
1
4
7
10/0
INDEX No.117 117
3 Press ID MODE SET.
The character on the selected monitor changes to
cyan while others change to red.
ON
ID MODE
SET
OFF
You can operate only the monitor specified. (All
operations are available in ID mode except
POWER ON/OFF.)
4 After the necessary adjustment, press ID MODE
OFF.
The monitor returns to the normal mode.
ON
ID MODE
SET
OFF
Input number
Index number