Sony DX100 Projector Accessories User Manual


 
22
The Connection/Power Menu
The Connection/Power Menu
The Connection/Power menu is used for setting for the connections and power.
*1: This may not be optimum depending on the input signal. In this case, set manually according to
the connected equipment.
*2: Select “Off” to avoid entering standby mode when there is no input signal.
*3: This varies depending on the “Lamp Mode” setting.
*4: As the lamp is dimmed gradually, you may not notice any change in brightness. You might only
notice that the lamp has dimmed when its brightness is restored after there is a change in input
signal.
*5: This mode does not work for about three minutes after the lamp lights. A change in signal may
not be detected depending on the input image. The lamp may become brighter at intervals if you
continue to use the projector during lamp dimming. However, this is not a malfunction. If With
No Input is set, it takes priority.
Items Item descriptions
Input-A Signal Sel.
*1
Auto/Computer/Video GBR/Component:
When set to “Auto,” selects
the type of video signal input automatically when “Input-A” is selected.
ECO
Lamp Mode High/Standard/Low/Auto
*5
: When set to “High,” the image becomes
brighter, and power consumption becomes higher. When set to “Low,”
power consumption is minimized; however, the image will be darker.
When set to “Auto,” brightness is adjusted automatically according to
image content. Dark images are projected with brightness adjusted,
leading to energy-saving. Bright images are projected brightly, without
adjusting brightness.
Auto Power Saving
With No Input Lamp Cutoff: The lamp turns off automatically and power
consumption is reduced if no signal is input for more than 10 minutes.
The lamp lights again when a signal is input or any key is pressed. In
Lamp Cutoff, the ON/STANDBY indicator lights in orange. (page 25)
Standby
*2
: If no signal is input to the unit for more than 10 minutes,
the power turns off automatically, and the unit enters standby mode.
Off: You can deactivate the With No Input.
With Static
Signal
Lamp Dimming
*4*5
: If an image does not change for about
10 seconds, lamp output is gradually reduced (approximately 10% to
15%
*3
) from that set in the Lamp Mode. Automatically the lamp slowly
darkens to approximately 30% of its lamp output according to the
selected time (with no change to input signal) “5,” “10,” “15,” “20
minutes or “Demo.,” While dimming the lamp, the message “Lamp
Dimming” appears. If you select “Demo.,” the image will start to
darken about 40 seconds later. When any change in signal is detected,
or an operation (remote control or control panel) is performed, normal
brightness is restored.
Off: You can deactivate the With Static Signal.
Direct Power On On/Off: When set to “On,” you can turn the power on without going to
Standby mode when the AC power cord is connected to a wall outlet.
With the projector turned off, you can also unplug the AC power cord
without going to Standby mode, regardless of the Direct Power On
setting.
Notes