– 38 –
KP-43T70C/53SV70C/61SV70C
RM-Y906 RM-Y906 RM-Y906
* In case of multiple error, last error is displayed.
[SENSOR POSITION]
• ERROR CODE SCREEN DISPLAY
* Error code will be displayed on center of screen for 3 seconds.
E 11 B
E 11 B
R. G. B
SENSOR NUMBER
ERROR CODE 10
ERROR
3
0
2
1
SCREEN
0 : UPPER SENSOR
1 : LEFT SENSOR
2 : RIGHT SENSOR
3 : LOWER SENSOR
• ERROR CODE DISPLAY IN REGI SERVICE MODE
PJE 2 9 1 4 0
ERR
ITEM NUMBER-29
ERROR CODE 40
SENSOR NUMBER
(ONLY "10"or "20")
R.G.B
G-0 (Blank)
R-1
B-2
3-11. AUTO REGISTRATION ERROR CODE LIST
00 No Error
10 Sensor Output Level Low * Check wiring, beam position, sensor. 0 : Upper Center
1 : Middle Left
2 : Middle Right
3 : Lower Center
20 Sensor Output Level High * Check OP-amp circuit. 0 : Upper Center
1 : Middle Left
2 : Middle Right
3 : Lower Center
30 Adjustment Loop Counter Overflow * Check the data go far from the standard or not.
40 Regi Data Overflow * Check the data go far from the standard or not.
50 Regi Data Overflow * Check the data go far from the standard or not.
60 Offset Overflow * Check the data go far from the standard or not.
70 Offset Overdrow * Check the data go far from the standard or not.
ERROR
DISCRIPTION NOTE
CODE