Sony SDM-M51D Computer Monitor User Manual


 
18
Troubleshooting
Before contacting technical support, refer to this section.
On-screen messages
If there is something wrong with the input signal, one of the
following messages appears on the screen. To solve the problem,
see Trouble symptoms and remedies on page 19.
If OUT OF SCAN RANGE appears on the screen
This indicates that the input signal is not supported by the
monitors specifications. Check the following items.
If xx.x kHz/xx Hz is displayed
This indicates that either the horizontal or vertical frequency
is not supported by the monitors specifications.
The figures indicate the horizontal and vertical frequencies of
the current input signal. The horizontal frequencies above
100 kHz and the vertical frequencies above 100 Hz are
represented by 99.9 kHz and 99 Hz, respectively.
If RESOLUTION > XGA is displayed
This indicates that the resolution is not supported by the
monitors specifications.
If NO INPUT SIGNAL appears on the screen
This indicates that no signal is input.
GO TO POWER SAVE
The monitor will enter the power saving mode after about 5
seconds from the message is displayed.
If CABLE DISCONNECTED appears on the screen
This indicates that the video signal cable has been disconnected.
GO TO POWER SAVE
The monitor will enter the power saving mode after about 5
seconds from the message is displayed.
OUT OF SCAN RANGE
xx . xkHz / xxHz
INFORMATION
NO I NPUT S IGNAL
GO TO POWER SAVE
INFORMATION
CABLE D ISCONNECTED
GO TO POWER SAVE
INFORMATION