Sony SDX-700C Computer Drive User Manual


 
27
Temperature and Humidity Range
Temperature
Operating 5˚C to 40˚C (T<10˚C/h) (41˚F to 104˚F (T<18˚F/h))
Non-operating (mech.) – 40˚C to 70˚C (T<20˚C/h) (– 40˚F to 158˚F (T<36˚F/h))
Non-operating (tape) – 40˚C to 45˚C (T<20˚C/h) (– 40˚F to 113˚F (T<36˚F/h))
Humidity
Operating 20 to 80% RH, non-condensing
Maximum wet bulb temperature = 26˚C (78.8˚F)
Non-operating (mech.) 5 to 95% RH (RH<30%/h)
Maximum wet bulb temperature = 45˚C (113˚F)
Non-operating (tape) 20 to 80% RH (RH<30%/h)
Shock
Operating No Data Loss
Half Sine
Performance
5 G Peak 3 ms
3 axes, 3 directions
*Interval of 10 seconds
Non-operating No Device Damage
Half Sine
90 G Peak 3 ms
(30 G Peak 11 ms)
3 axes, 3 directions
*Interval of 10 seconds
Air-cooling Requirement
Surrounding temperature < 40˚C (104˚F)
Clean air flow is recommended to minimize the possibility of data loss.
Power Requirements
Voltage Max Ripple
Current
Typical Maximum
5 V +/– 5 % 100 mVp-p 1.5 A 2.5 A
12 V +/– 10 % 150 mVp-p 0.75 A 3.0 A