Specifications
Tilting the unit more than 15
degrees
Avoid using as the unit tilts more than 15
degrees. These installation may cause
malfunction.
Blocking the ventilation holes
Avoid using something to cover over the
ventilation holes (exhaust/intake);
otherwise, the internal heat may build up.
Removing the adjusters
Avoid using the unit with the adjusters
removed. Blocking the ventilation holes
(intake) may cause internal heat build-up.
Specifications
Optical characteristics
Projection system
3 LCD panels, 1 lens, projection
system
LCD panel 0.9-inch TFT LCD panel with
micro-lens array, 2,359,296
pixels (786,432 pixels × 3)
Lens 1.3 times zoom lens
f 33.6 to 42 mm/F 1.7 to 2.2
Lamp 160 W
Projection picture size
Range: 40 to 300 inches (diagonal
measure)
Light output ANSI lumen
1)
1500 lm
Throwing distance
(When the XGA signal is input)
40-inch: 1465 to 1768 mm
(57
3
/
4
to 69
5
/
8
inches)
60-inch: 2230 to 2683 mm
(87
7
/
8
to 105
3
/
4
inches)
80-inch: 2996 to 3598 mm
(118 to 141
3
/
4
inches)
100-inch: 3761 to 4513 mm
(148
1
/
8
to 177
3
/
4
inches)
120-inch: 4526 to 5428 mm
(178
1
/
4
to 213
3
/
4
inches)
150-inch: 5674 to 6800 mm
(223
1
/
2
to 267
3
/
4
inches)
180-inch: 6822 to 8172 mm
(268
5
/
8
to 321
7
/
8
inches)
200-inch: 7587 to 9087 mm
(298
3
/
4
to 357
7
/
8
inches)
250-inch: 9500 to 11375 mm
(374
1
/
8
to 448 inches)
300-inch: 11413 to 13662 mm
(449
1
/
2
to 538 inches)
1) ANSI lumen is a measuring method of
American National Standard IT 7.228.
15˚
15˚
15˚