Sony VPLFX52 Projector User Manual


 
44
VPL-CX61/CX63/CX75/CX76/CX80/CX85/CX86/FE40/FE40L/FX40/FX40L/FX51/FX52/FX52L/PX35/PX40/PX41
<Table 1> <Table 2>
Item Number Data Remarks
Item Upper byte Lower byte Data Upper byte Lower byte
STATUS ERROR 01h 01h NO ERROR 00h Get only
LAMP ERROR 01h
FAN ERROR 02h
COVER ERROR 04h
TEMP ERROR 08h
D5V ERROR 10h
POWER ERROR 20h
WARNING ERROR 40h
NVM Data ERROR 80h
STATUS POWER 01h 02h STANBY 00h
START UP 01h
STARTUP LAMP 02h
POWER ON 03h
COOLING1 04h
COOLING2 05h
SAVING COOLING1 06h
SAVING COOLING2 07h
SAVING STABY 08h
LAMP TIMER 01h 13h USE TIME 0000h-ffffh
*1
SUB ROM VERSION 01h 1Dh SUB ROM VERSION
*2
SC1 ROM VERSION 01h 1Eh SC ROM VERSION
*2
STATUSSECRITY 01h 1Fh Disable 00h 00h
Enable 00h 01h
Sircs (PROJECTORn Category) 17h Refer to table 18 _ 00h 00h Set only
*3
Sircs (PROJECTORnE Category) 19h Refer to table 19 _ 00h 00h
(VPL-FE40/FE40L/FX40/FX40L)
<Table 3>
Item Number Data
Item Data Upper byte Lower byte
ACK _ 00h 00h
NAK Undefined Command 01h 01h
Size Error 04h
Select Error 05h
Range Over 06h
Not Applicable 0Ah
Check Sum Error F0h 10h
Framing Error 20h
Parity Error 30h
Over Rub Error 40h
Other Comm Error 50h
(VPL-FE40/FE40L/FX40/FX40L)
*1 Example) In case the lamp timer indicates
1000H, return values are [03h] upper byte
and [E8h] lower byte.
*2 Example) In case the software version is 1.03,
return values are [01h] upper byte and [03h]
lower byte.
*3 It is corresponded to single command only.
The await-return time of return value is approx. 200
msec.
m
. This is the case, unless the communications are
interfered anyway.
. It takes longer time according to the command.
. The standby mode is set to “Low”, and when the
main body of the projector is a standby, only
POWER ON/OFF and POWER ON of the
PROJECTERn category of SIRCS are effective.