MAINS VOLTAGE SELECTION
Special attention should be paid to the following information:
Do not change the voltage setting without first
turning the unit off and unplugging the mains lead.
This unit is capable of operating over a range of mains voltages by means of a
4-position mains input fuse carrier. It is important to ensure that the correct voltage
setting is selected for the level of local mains voltage supply, for safe, uninterrupted
operation of the unit. Voltage selection is achieved by positioning the fuse carrier so
that the required voltage appears next to the arrow which is moulded in the connector.
In this way the unit is set up for operation at one of the following ranges of mains
supply:
NOMINAL VOLTAGE OPERATING VOLTAGE RANGE
(+10/-15%)
Vrms AC Vrms AC
230 196 - 253
115 98 - 126
100 85 - 110
85 73 - 93
To remove the fuse use a small screwdriver to prise the fuse carrier from its location
in the connector.
To avoid risk of fire use the correct value fuse, as
indicated on the unit.
REPLACING MAINS FUSE
Switch the ON/OFF switch to the OFF position. Remove the mains lead from the
connector. Use a small screwdriver to prise the fuse carrier from its location in the
connector. Check the fuse and replace if necessary; also check that the voltage
selection is correct for the mains supply level before switching the unit ON again.
In the event of repeated failure of the mains fuse consult the Soundcraft dealer from
where the unit was purchased.
This unit contains no user serviceable parts. Refer
all servicing to a qualified service engineer, through
the appropriate Soundcraft dealer.