Speedotron D1604 Power Supply User Manual


 
18 19
DESCRIPTION OF CONTROLS
Power turns power supply on and off. (Flashes light units when turning off.)
Model turns model lamps on and off.
Symmetrical/Asymmetrical controls power distribution. In the symmetrical position,
power is split equally between all lights. In the asymmetrical position power is
distributed unequally and the model lamp brightness/flash tube output of a light
in outlet #2 is reduced.
Ready/Push to Flash a combination ready light and test flash button. Illuminates to
indicate when power supply has recycled to 85%. Pressing the button when
illuminated triggers the flash for testing or open flash applications.
Sync socket for sync extension or slave.
Circuit Breaker/Reset resets circuit breaker. Circuit breaker disables power supply in
case of malfunction. Does not affect model lamp circuit.
Light Unit Outlets (2) sockets for connecting one or two light units to power supply.
TECHNICAL SPECIFICATIONS
D402 Power Supply
Maximum power: . . . . . . . . . . . . . . . . . . . . .400Ws
Number of light unit outlets: . . . . . . . . . . . .4
Recycle time: watt-seconds seconds
(to 85% voltage, ANSI standard) . . . . . . . . . . . . .400 1.75
200 0.9
Flash duration : . . . . . . . . . . . . . . . . . . . . . . .1/1200 sec. (.8 milliseconds)
(at full power w/one M11Q light unit measured 1/2 to 1/2 peak as per ANSI PH3.40)
Maximum power into one light unit: . . . . . . .400Ws
Minimum power into one light unit: . . . . . . .150Ws
Minimum power per light with 4 light units: .15Ws
Power input requirements: . . . . . . . . . . . . . .105-120VAC 50-60Hz. 10 amps peak
Size: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5.5 x 7.9" (foot print) x 7.2" (case height)
Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11.5 lbs
System voltage: . . . . . . . . . . . . . . . . . . . . . . .900V
Trigger voltage: . . . . . . . . . . . . . . . . . . . . . . .70V
Trigger current: . . . . . . . . . . . . . . . . . . . . . . .0.000043A (43 micro-amps)
Guide number : . . . . . . . . . . . . . . . . . . . . . . .270
(at ISO 100 w/M11Q fitted 11-1/2" reflector measured at 10 feet, on axis with MW9QC flash tube)
D802 Power Supply
Maximum power: . . . . . . . . . . . . . . . . . . . . .800Ws
Number of light unit outlets: . . . . . . . . . . . .4
Recycle time: watt-seconds seconds
(to 85% voltage, ANSI standard) . . . . . . . . . . . . .800 3.2
400 2
Flash duration : . . . . . . . . . . . . . . . . . . . . . . .1/830 sec. (2.9 milliseconds)
(at full power w/one M11Q light unit measured 1/2 to 1/2 peak as per ANSI PH3.40)
Maximum power into one light unit: . . . . . . .800Ws
Minimum power into one light unit: . . . . . . .150Ws
Minimum power per light with 4 light units: .30Ws
Power input requirements: . . . . . . . . . . . . . .105-120VAC 50-60Hz. 10 amps peak
Size: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5.5 x 7.9" (foot print) x 7.2" (case height)
Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 lbs
System voltage: . . . . . . . . . . . . . . . . . . . . . . .900V
Trigger voltage: . . . . . . . . . . . . . . . . . . . . . . .70V
Trigger current: . . . . . . . . . . . . . . . . . . . . . . .0.000043A (43 micro-amps)
Guide number : . . . . . . . . . . . . . . . . . . . . . . .380
(at ISO 100 w/M11Q fitted 11-1/2" reflector measured at 10 feet, on axis with MW9QC flash tube)
Ready/Push to flash
Symmetrical/Asymmetrical
Power
Model
Push to reset
Sync
Light unit outlets