SMSC USB3250 Network Card User Manual


 
Hi-Speed USB Device Transceiver with UTMI Interface
Revision 1.7 (05-11-07) 6 SMSC USB3250
PRODUCT PREVIEW
Table 2 Data Interface Pins
NAME DIRECTION
ACTIVE
LEVEL DESCRIPTION
DATA[15:0] Bidir N/A
DATA BUS. 16-BIT BIDIRECTIONAL MODE.
TXVALID RXVALID VALIDH DATA[15:0]
0 0 X Not used
0 1 0 DATA[7:0] output is valid
for receive
VALIDH is an output
0 1 1 DATA[15:0] output is
valid for receive
VALIDH is an output
1 X 0 DATA[7:0] input is valid
for transmit
VALIDH is an input
1 X 1 DATA[15:0] input is valid
for transmit
VALIDH is an input
DATA BUS. 8-BIT UNIDIRECTIONAL MODE.
TXVALID RXVALID DATA[15:0]
00Not used
0 1 DATA[15:8] output is valid for receive
1 X DATA[7:0] input is valid for transmit
TXVALID Input High Transmit Valid. Indicates that the TXDATA bus is valid for
transmit. The assertion of TXVALID initiates the transmission of
SYNC on the USB bus. The negation of TXVALID initiates EOP
on the USB.
Control inputs (OPMODE[1:0], TERMSELECT,XCVRSELECT)
must not be changed on the de-assertion or assertion of TXVALID.
The PHY must be in a quiescent state when these inputs are
changed.
TXREADY Output High Transmit Data Ready. If TXVALID is asserted, the SIE must
always have data available for clocking into the TX Holding
Register on the rising edge of CLKOUT. TXREADY is an
acknowledgement to the SIE that the transceiver has clocked the
data from the bus and is ready for the next transfer on the bus. If
TXVALID is negated, TXREADY can be ignored by the SIE.
VALIDH Bidir N/A Transmit/Receive High Data Bit Valid (used in 16-bit mode
only). When TXVALID = 1, the 16-bit data bus direction is
changed to inputs, and VALIDH is an input. If VALIDH is asserted,
DATA[15:0] is valid for transmission. If deasserted, only DATA[7:0]
is valid for transmission. The DATA bus is driven by the SIE.
When TXVALID = 0 and RXVALID = 1, the 16-bit data bus
direction is changed to outputs, and VALIDH is an output. If
VALIDH is asserted, the DATA[15:0] outputs are valid for receive.
If deasserted, only DATA[7:0] is valid for receive. The DATA bus
is read by the SIE.
RXVALID Output High Receive Data Valid. Indicates that the RXDATA bus has received
valid data. The Receive Data Holding Register is full and ready to
be unloaded. The SIE is expected to latch the RXDATA bus on the
rising edge of CLKOUT.
RXACTIVE Output High Receive Active. Indicates that the receive state machine has
detected Start of Packet and is active.
RXERROR Output High Receive Error. 0: Indicates no error. 1: Indicates a receive error
has been detected. This output is clocked with the same timing as
the RXDATA lines and can occur at anytime during a transfer.