Sun Microsystems Interface Adapter Network Card User Manual


 
16 Sun PCI High Speed Quad Port Serial Interface Adapter User’s Guide December 2005
4. Add the client site hosts on the server machine and add the server site hosts on
the client machine.
a. Edit the server’s /etc/hosts file and add the client site local hosts.
b. Edit the client’s /etc/hosts file and add the server site local hosts.
Note Both IP addresses have to be on the same subnet.
Refer to the hosts(4) man page and the sample /etc/hosts files:
5. Edit the /etc/netmasks file as follows:
6. Start the PPP connection by typing the following commands:
boot -r
#Server site (/etc/hosts)
#=======================
#local
192.10.10.10 qa8a-hihp0
193.10.10.10 qa8a-hihp1
194.10.10.10 qa8a-hihp2
195.10.10.10 qa8a-hihp3
#remote
192.10.10.20 qa1b-hihp0
193.10.10.20 qa1b-hihp1
194.10.10.20 qa1b-hihp2
195.10.10.20 qa1b-hihp3
# Client site (/etc/hosts)
# =======================
#local
192.10.10.20 qa1b-hihp0
193.10.10.20 qa1b-hihp1
194.10.10.20 qa1b-hihp2
195.10.10.20 qa1b-hihp3
# remote
192.10.10.10 qa8a-hihp0
193.10.10.10 qa8a-hihp1
194.10.10.10 qa8a-hihp2
195.10.10.10 qa8a-hihp
192.10.10.0 255.255.255.0
193.10.10.0 255.255.255.0
194.10.10.0 255.255.255.0
195.10.10.0 255.255.255.0
/etc/rc2.d/S47pppd stop
/etc/rc2.d/S47pppd start