Chapter2:ConguringtheLSIMegaRAIDSettings
2-11
ConguringDrivesManually
1. In the Add Conguration screen, select Manual Conguration and click Next
to begin adding drives. The following screen displays.
Add Drives
2. Select the drives you want to add to the array and click Add to Array. To
undo any drive addition, select the drive and click Reclaim.
3. After all desired drives are added to the drive group, select Accept DG to
create a drive group. Multiple drive groups can be created by adding addi-
tional available drives. When nished creating drive groups, select Next.
4. In the pull-down menu of the Span Denition screen, select the drive group
you want to add to SPAN and click Add to SPAN, then click Next.
SpanDenition
Note: For RAID 10, 50, and 60, two or more drive groups must be added
to SPAN.