Tatung TLM-1906 Computer Monitor User Manual


 
16
6. Regulatory Agency
6.1 Safety Approvals
This series design shall meet the standards of the following domestic and foreign
agencies:
UL listed: UL60950-2000 listing (Information Processing and Business Equipment)
CUL Certified: CAN/CSA C22.2 No. 950-95 (Information Technology Equipment)
CE LVD: IEC 60950: 1999 3
rd
edition
CB: IEC 60950: 1999 3
rd
edition
6.2 EMI/EMS Emission Approvals
This series design shall meet following EMI/EMS specifications:
FCC Compliance: FCC Rules and Regulations, Part 15, subpart B, Class B.
CE COMPLIANCE: EN55022:1998 class B, EN55024:1998, EN50130-4:1998
EN 61000-3-2:2000, EN 61000-3-3:1995.
7. Mechanical
7.1 Weight
Model TLM1-1506 TLM-1706 TLM-1906
Net weight 4.1 KG/ 9.0 lb 5.0 KG/ 11.0 lb 6.4 KG/ 14.5 lb
Gross weight 5.8 KG/ 13.0 lb 6.8 KG/ 15.0 lb 8.6 KG/ 19.0 lb
7.2 Dimensions:
Model TLM-1506 TLM-1706 TLM-1906
Physical dimension
356(W) x 387(H) x 200(D)mm
14.0(W) x 15.2(H) x 7.9(D)inch
387(W) x 402(H) x 200(D)mm
15.2(W) x 15.8(H) x 7.9(D)inch
458(W) x 416(H) x 215(D)mm
18.0(W) x 16.4(H) x 8.5(D)inch
Packing dimension
432(W) x 470(H) x 203(D)mm
17.0(W) x 18.5(H) x 8.0(D)inch
450(W) x 470(H) x 203(D)mm
17.7(W) x 18.5(H) x 8.0(D)inch
546(W) x 521 (H)x 220(D)mm
21.5(W) x 20.5(H) x 8.7(D)inch
7.3 Wall mount:
Optional wall mount (VESA standard 100mmX100mm)
8. Reliability
Mean Time Between Failures (MTBF):
MTBF shall be 50,000 hours minimum at 90% confidence level and 100% duty cycle
continuous operation at 25
o
C. The calculation shall not include LCD panel.