TDK 750W Power Supply User Manual


 
83
-
507
-
013 Rev. D
62
7.10.6
Status Control Commands
Refer to Section 7
-
8 for definition of the registers.
#
Co
mmand
Description
1
STT?
Reads the complete power supply status.
Returns ASCII characters representing the following data, separated by commas:
MV<actual (measured) voltage> PC<programmed (set) current>
PV<programmed (set) voltage>
SR<status register, 2
-
digit hex>
MC<actual (measured) current> FR<fault register, 2
-
digit hex>
Example response: MV(45.201),PV(45), MC(4.3257), PC(10), SR(30), FR(00)
2
FLT?
Reads Fault Conditional Register. Returns 2
-
digit hex.
3
FENA
Set Fault Enable Register using 2
-
digit hex.
4
FENA?
Reads Fault Enable Register. Returns 2
-
digit hex.
5
FEVE?
Reads Fault Event Register. Returns 2
-
digit hex. Clears bits of Fault Event Register.
6
STAT?
Reads Status Conditional Register. Retur
ns 2
-
digit hex.
7
SENA
Sets Status Enable Register using 2
-
digit hex.
8
SENA?
Reads Status Enable Register. Returns 2
-
digit hex.
9
SEVE?
Reads Status Event register. Returns 2
-
digit hex. Clears bits of Status Event register.
7.11 STATUS, ERROR AND SR
Q REGISTERS
7.11.1 General Description
This Section describes the various status error and SRQ registers structure. The registers can be
read or set via the RS232/RS485 commands. When using the IEEE option, refer to the User’s Manual
for Gen
e
sys
TM
Power Su
pply IEEE Programming Interface.
Refer to Fig. 7
-
7 for the Status and Error Registers Diagram.