TDK FReta Series Network Card User Manual


 
Data Sheet: FReta iEB Series –Single Output Eighth Brick Bus Converter
©2004-2006 TDK Innoveta Inc.
1/24/2008
(877) 498
-
0099
13/13
Safety Considerations:
Check with TDK Innoveta for the current
status of safety approval on the iEB product
family.
For safety agency approval of the system in
which the DC-DC power module is installed,
the power module must be installed in
compliance with the creepage and clearance
requirements of the safety agency. The
isolation is basic insulation. For
applications requiring basic insulation, care
must be taken to maintain minimum
creepage and clearance distances when
routing traces near the power module.
As part of the production process, the power
modules are hi-pot tested from primary and
secondary at a test voltage of 1500Vdc.
To preserve maximum flexibility, the power
modules are not internally fused. An
external input line normal blow fuse with a
maximum value of 10A is required by safety
agencies. A lower value fuse can be
selected based upon the maximum dc input
current and maximum inrush energy of the
power module.
When the supply to the DC-DC converter is
less than 60Vdc, the power module meets
all of the requirements for SELV. If the
input voltage is a hazardous voltage that
exceeds 60Vdc, the output can be
considered SELV only if the following
conditions are met:
1) The input source is isolated from the
ac mains by reinforced insulation.
2) The input terminal pins are not
accessible.
3) One pole of the input and one pole
of the output are grounded or both
are kept floating.
4) Single fault testing is performed on
the end system to ensure that under
a single fault, hazardous voltages
do not appear at the module output.
Warranty:
TDK Innoveta’s comprehensive line of
power solutions includes efficient, high-
density DC-DC converters. TDK Innoveta
offers a three-year limited warranty.
Complete warranty information is listed on
our web site or is available upon request
from TDK Innoveta.
Information furnished by TDK Innoveta is believed to be accurate and reliable. However, TDK Innoveta assumes no
responsibility for its use, nor for any infringement of patents or other rights of third parties, which may result from its use. No
license is granted by implication or otherwise under any patent or patent rights of TDK Innoveta. TDK Innoveta components
are not designed to be used in applications, such as life support systems, wherein failure or malfunction could result in injury
or death. All sales are subject to TDK Innoveta’s Terms and Conditions of Sale, which are available upon request.
Specifications are subject to change without notice.
is a trademark or registered trademark of TDK Corporation.
3320 Matrix Drive Suite 100
Richardson, Texas 75082
Phone (877) 498-0099 Toll Free
(469) 916-4747
Fax (877) 498-0143 Toll Free
(214) 239-3101
support@tdkinnoveta.com