Texas Instruments UCC28060EVM Power Supply User Manual


 
5TestSetupandPower-Up/Power-DownInstructions
Isolation Transformer
0 to 300W Load
VM
+
13V Bias Supply
TestSetupandPower-Up/Power-DownInstructions
www.ti.com
WARNING
Therearehighvoltagespresentonthepre-regulator.Itshouldonly
behandledbyexperiencedpowersupplyprofessionals.To
evaluatethisboardassafelyaspossible,thefollowingtest
configurationshouldbeused:
Connectanisolationtransformerbetweenthesourceandunit
Attachavoltmeterandaresistiveorelectronicloadtotheunit
outputbeforesupplyingpowertotheEVM.
Aseparate13-VbiassupplyisrequiredtopowertheUCC28060controlcircuitry.Theunitwillstartup
underno-loadconditions.However,forsafety,aloadshouldbeconnectedtotheoutputofthedevice
beforeitispoweredup.Theunitshouldalsoneverbehandledwhilepowerisappliedtoitorwhenthe
outputvoltageisabove50-Vdc.RefertoFigure3forarecommendedtestsetupdiagram.
CAUTION
Thereareveryhighvoltagesontheboard.Componentscanandwillreach
temperaturesgreaterthan100°C.UsecautionwhenhandlingtheEVM.
Figure3.TestSetup
UCC28060EVM300-WInterleavedPFCPre-Regulator 4SLUU280BMay2007RevisedJuly2008
SubmitDocumentationFeedback