Texas Memory Systems RamSam-210 Computer Drive User Manual


 
- 16 -
4.5 MCP Commands
4.5.1 EXIT
The exit command is used to close a monitor session. The “QUIT” command also
performs the same action.
4.5.2 HELP
The “HELP command provides a brief online description of each command that is
available. Commands that require parameters are listed with the “<parameters>” as
options. Commands with optional parameters are listed with the “[parameters]” as
options.
4.5.3 CONFIGSYS
The system configuration utility allows you to configure various system dependant
options. Currently, the only option available is the amount of time the management
controller waits after power loss before it initiates an automatic shutdown.
** Ethernet configuration utility **
1. Set time to wait after losing power before system shutdown
Q. Exit
Select:
By selecting option “1” you may set the power down delay to be between 1 and 15
minutes. The default value is 5 minutes.
4.5.4 FIRMWARE
The “FIRMWARE” command shows the firmware revision levels for various components
in the RamSan-210. This command is mainly for internal use for tracking firmware
revision levels.
4.5.5 IPCONFIG
The Ethernet monitor port is configured using the “IPCONFIG” command. The
RamSan-210 supports IP assignment through DHCP, BOOTP, RARP, or setting a static
IP. This command may only be used from the serial port since it involves changing the
network settings. Here is a demonstration of the command:
ram-san> ipconfig
** Ethernet configuration utility **
IP assignment mode = RARP
Hostname = ram-san
Ethernet MAC Address = 00:20:c2:00:08:05