PRODUCT SCOPE
Frame Size
5010/5810 Multi-Mount; Direct
Coupled and Belt Drive ( 4-Pole and
Greater)
Pole Speed 2, 4, 6, and 8-Pole
Target Output 2-Pole 4-Pole 6-Pole 8-Pole
5009/10/11 TEFC
Up to
450 HP
Up to
500 HP
Up to
450 HP
Up to
250 HP
5809/10/11 TEFC
Up to
600 HP
Up to
800 HP
Up to
700 HP
Up to
500 HP
Voltage
2300 V or 4000 V
(Optional Dual-Voltage Available)
Frequency 60 Hz
Insulation Class F
Service Factor 1.15
Time Rating Continuous
Applicable
Standards
NEMA MG-1, API 541 (As
Requested), CSA (Class I, Division
2), CSA Construction
OPERATING CONDITIONS
Ambient -20° to 40°C
Humidity Less than 100%
Altitude Less than 3300 ft. (1000 m)
Enclosure TEFC, Cast Iron Fin-Type
Starting Method Direct On-Line, per NEMA
Starting Duty (1) Hot, (2) Cold
Allowable Wk²
Per NEMA MG-1; 1/2 Wk² for
2-Pole
Area Classication
Class I, Division 2, Group C & D
(T3 Temperature Code)
BEARING DETAILS
Type
Anti-Friction Bearing as Standard;
Sleeve Bearing Available on 2-Pole
Lubrication
Grease Lubrication; Oil on Sleeve
Bearing
Temperature
55°C Rise Maximum at 1.15 Service
Factor by RTD; 53°C Rise Maximum
at 1.15 Service Factor When Sleeve
Bearing is Specied
Insulation OS Insulation Bearing
Grease Chevron SRI or Equivalent
CONSTRUCTION DETAILS
Mounting Horizontal Foot Mounting
Direction of
Rotation
CCW from ODE (CW Option)
T-Box Location DE Side as Standard; Cast Iron
Number of Leads Three
Shaft Material Minimum 1045 Hot-Rolled
Core Plate C5
Frame/Brackets Cast Iron
Rotor Cage Aluminum Die Cast
Construction Non-Sparking
5011
2-Pole
5811
2-Pole
5011
4-Pole, 6-Pole, 8-Pole
5811
4-Pole, 6-Pole, 8-Pole