© 2006 - 2008 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221
DIALING/COMMUNICATION CONTROL
3 - 19
3
- Communication end procedure
This procedure is to terminate the communication. The transmission rate is 1,200 bps.
Transmitter
Receiver
Signal name Abbreviation Function Remarks
Sh signal Sh Short training
Sh signal Sh
ALT signal ALT -
E sequence E -
End of procedure signal PPS-EOP The transmission of one page
is completed.
Flag flags Maintains the synchroniza-
tion.
7E (H)
Disconnection signal DCN Informs to disconnect the line.
Signal name Abbreviation Function Remarks
Sh signal Sh Short training
Sh signal Sh
ALT signal ALT -
E sequence E -
Flag flags Maintains the synchroniza-
tion.
7E (H)
Message confirmation MCF Indicates that the image sig-
nal is received normally, and
the receiver is ready to
receive the next page.