PACKAGE CONTENTS
5
• TRIBUTARIES® PWRI-PRO AC outlet with built in AC power line filtering as well as surge suppression
and under/over-voltage protection.
• Packed with four mounting screws and 3 wire nuts for termination to in-wall building wire.
• Installation & Operation Guide
INSTALLATION OVERVIEW
CAUTION: This product must be installed by a licensed electrician in accordance with the
National Electrical Code.
Turn off power at circuit breaker before attempting installation
INSTALL OUTLET BOXES:
1. Install a dual gang wall outlet box (not included) in the wall near the display or projector.
•FitsstandardCarlon®superblue™plasticinwallboxes
•FitsstandardRaco®metalboxesttedwithaminimumof½”coverplate
2. Run a minimum of 14AWG solid copper building wire (i.e.: ROMEX) thru the rear opening
of the outlet box. Leave about 3 inches of wire extending thru the box.
CONNECTING PWRI-PRO OUTLET:
1. Connect building wire to PWRI-PRO outlet. First connect the ground wire to the green
wire coming from the rear of the PWRI-PRO using the supplied wire nut. Second connect
the white wires together using a supplied wire nut. Last, connect the black wires together
using a supplied wire nut
2. Carefully fold wires into the outlet box and secure the PWRI-PRO outlet to the box with the
included screws.
TURN ON POWER:
1. Turn on the power at the circuit breaker.
2. POWER ON LED will illuminate and blink for five seconds while it checks for stable incoming
voltage between 90VAC and 135VAC. Then, once stable voltage has been determined, the
LED will stay on indicating the outlets are powered.
3. PROTECTED LED will illuminate indicating surge suppression electronics are operating.
4. Test the outlets for proper polarized power before plugging in any electronics.
ENGLISH