Tripp Lite 2POSTRMKITWM Network Card User Manual


 
Rack Mounting
continued
2-Post Mounting
Mount 1U UPS models in 2-post racks with included hardware following the procedure below.
If you mount 2U UPS models in 2-post racks, they require the addition of a Tripp Lite 2-Post
Rackmount Installation Kit (model: 2POSTRMKITWM, sold separately). See Installation Kit
owner’s manual for installation procedure for 2U UPS models.
Attach mounting ears to the front mounting holes of
your equipment using the screws provided . The ears
should face backward.
Using an assistant if necessary, lift your equipment
and slide it onto the mounting shelves. Attach your
equipment to the rack by passing the screws, nuts and
washers provided through its mounting ears and
into the rack rails.
D
CB
A
1
2
B
A
D
C
1
2
Tower Mounting
4
Mount all UPS models in an upright, tower position using included hardware. The user must deter-
mine the fitness of hardware and procedures before mounting.
All UPS Models
Stand your UPS on its side with the LED/Control panel at
the top. Attach one rack mounting ear to each side of the
UPS using included screws . Attach the rack mounting
ears to the floor with user-supplied hardware.
2U UPS Models Only
Rotate the LED/Control panel to view it easier while the
UPS is tower mounted. Insert a small screwdriver, or other
tool, in the slots on either side of the panel. Pop the panel
out; rotate it; and pop the panel back in place.
B
A
A
B