Important Safety Instructions
UPS Location Warnings
Install your UPS indoors, away from excess moisture or heat, conductive contaminants, dust or direct
sunlight.
For best performance, keep the indoor temperature between 32º F and 104º F (0º C and 40º C).
Leave adequate space around all sides of the UPS for proper ventilation.
UPS Connection Warnings
Connect your UPS directly to a properly grounded AC power outlet. Do not plug the UPS into itself;
this will damage the UPS.
Do not modify the UPS’s plug, and do not use an adapter that would eliminate the UPS’s ground
connection.
Do not use extension cords to connect the UPS to an AC outlet. Your warranty will be voided if anything
other than Tripp Lite surge suppressors are used to connect your UPS to an outlet.
If the UPS receives power from a motor-powered AC generator, the generator must provide clean,
filtered, computer-grade output.
Equipment Connection Warnings
Use of this equipment in life support applications where failure of this equipment can reasonably be expected to
cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended.
Do not use this equipment in the presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide.
Do not connect surge suppressors or extension cords to the output of your UPS. This might damage the
UPS and will void the surge suppressor and UPS warranties.
Battery Warnings
Your UPS does not require routine maintenance. Do not open your UPS for any reason. There are no user-
serviceable parts inside.
Batteries can present a risk of electrical shock and burn from high short-circuit current. Observe proper
precautions. Do not dispose of the batteries in a fire. Do not open the UPS or batteries. Do not short or
bridge the battery terminals with any object. Unplug and turn off the UPS before performing battery
replacement. Use tools with insulated handles. There are no user-serviceable parts inside the UPS. Battery
replacement should be performed only by authorized service personnel using the same number and type of
batteries (sealed Lead-Acid). The batteries are recyclable. Refer to your local codes for disposal
requirements or in the USA only call 1-800-SAV-LEAD or 1-800-8-BATTERY (1-800-822-8837) or visit
www.rbrc.com for recycling information. Tripp Lite offers a complete line of UPS System Replacement
Battery Cartridges (R.B.C.).Visit Tripp Lite on the web at www.tripplite.com/support/battery/index.cfm to
locate the specific replacement battery for your UPS.
Do not attempt to add external batteries to the UPS.
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the installation, operation
and storage of all Tripp Lite UPS Systems. Failure to heed these warnings will void your warranty.
Basic Operation
ON/OFF/
TEST Button
ON/OFF
LED
OVERLOAD/
CHECK
BATTERY LED
Battery Backup/
Surge Protected
Outlets
Tel/DSL Jacks
Resettable
Circuit Breaker
1
2
3
4
7
12V DC
Connector
8
5
“ON/OFF/TEST” Button
To turn the UPS on: Press and hold the ON/OFF/TEST Button for one second. If utility power is absent,
pressing the Button will “cold-start” the UPS, i.e. turn it on and supply power from its batteries.*
To turn the UPS off: Press and hold the ON/OFF/TEST Button for one second.* The UPS will be turned
completely off (deactivated).
To run a Self-Test: With your UPS plugged in and turned ON, press and hold the ON/OFF/TEST button
for three seconds.
* If fully charged.