Tripp Lite BC Pro Network Card User Manual


 
9
Manual del usuario
1111 W. 35th Street Chicago, IL 60609 EE.UU.
Atención al cliente: +1 (773) 869-1234 • www.tripplite.com
Importantes instrucciones de seguridad
10
Instalación rápida
11
Operación básica
12
Almacenamiento y servicio
15
Ficha técnica
15
BC Pro
®
Sistemas de energía ininterrumpible de 120V de entrada/salida
© 2003 Tripp Lite. Todos los derechos reservados. BC Pro
®
es una marca registrada de Tripp Lite.
English
1
Français
17
8
Specifications
Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.
Model: BCPRO600 BCPRO850 BCPRO1050 BCPRO1400
Series: AGOM1000USBKSR6 AGOM1050PJR61 AGOM1050PJR61 AGOM1400PSR61
Input Voltage/Frequency: 120V/60 Hz 120V/60 Hz 120V/60 Hz 120V/60 Hz
Output Capacity (VA/Watts): 600/345 850/600 1050/705 1400/940
Battery Runtime
(Half Load/Full Load) Minutes: 19/7 21/6 23/7 24/8
Battery Recharge Time: 2-4 hrs. 2-4 hrs. 2-4 hrs. 2-4 hrs.
Approvals: UL, cUL, NOM UL, cUL, NOM UL, cUL, NOM UL, cUL, NOM
ALL UNITS:
Output Waveform Line Mode (filtered sinewave); Output Waveform Battery Mode (PWM sine wave); AC Surge Suppression (exceeds
IEEE 587 Cat. A & B standards); AC Noise Attenuation (>40 dB at 1MHz); AC Protection Modes (H to N, H to G, N to G).
FCC RADIO/TV INTERFERENCE NOTICE:
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause
interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined by turning the device off and on,
the user is encouraged to try to correct the interference using one or more of the following measures: reorient or relocate the receiving
antenna; increase the separation between the equipment and receiver; connect the equipment into an outlet on a circuit different from
that which the receiver is connected; consult the dealer or an experienced radio/television technician for help. The user must use shielded
cables and connectors with this product. Any changes or modifications to this product not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
CONSUMER INFORMATION AND FCC REQUIREMENTS (U.S.A. ONLY, select models)
1. This equipment complies with Part 68 of the FCC rules. On the top or bottom of this equipment is a label that contains, among
other information, the FCC registration number for this equipment. If requested, provide this information to your telephone company.
2. If your Fax/Modem Protector causes harm to the telephone network, the telephone company may temporarily discontinue your
service. If possible, they will notify you in advance. But if advance notice isn't practical, you will be notified as soon as possible.
You will be advised of your right to file a complaint with the FCC.
3. Your telephone company may make changes in its facilities, equipment, operations or procedures that could affect the operation
of your equipment. If they do, you will be given advance notice so as to give you an opportunity to maintain uninterrupted service.
4. If you experience trouble with this Fax/Modem Protector, please contact Tripp Lite Customer Support, 1111 W. 35th Street,
Chicago, Illinois 60609; Phone (773) 869-1234 for repair/warranty information. The telephone company may ask you to
disconnect this equipment from the network until the problem has been corrected or you are sure that the equipment
is not malfunctioning.
5. This equipment may not be used on coin service provided by the telephone company. Connection to party lines is subject to state
tariffs. (Contact your state public utility commission or corporation for information.)
EQUIPMENT ATTACHMENT LIMITATIONS (MODELS WITH THE INDUSTRY CANADA LABEL IN CANADA ONLY)
Notice: The Industry Canada label identifies certified equipment. This certification means that the equipment meets the telecommunications
network protective, operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements
Document(s). The Department does not guarantee the equipment will operate to the user’s satisfaction.
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications
company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that the
compliance with the above conditions might not prevent degradation of service in some situations.
Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any repairs or alterations
made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request
the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal
metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. Caution:
Users should not attempt to make connections themselves, but should contact the appropriate electric inspection authority, or electrician,
as appropriate.
UL1778