Specifications
No. of AC Line Cord* No. of Control AC Energy Surge Transient Ultimate
AC Receptacles Length Switches Absorption Suppression Response Dimensions Lifetime
Model (NEMA5-15R) (ft.) Master/Aux. (joules) (amp spikes)** Time (H x W x D, in.) Insurance
TOUCHMASTER 6 10 1/4 1280 96,000 0 ns. 15/8 x 131/4 x 121/2 $25,000
(MT-6)
TOUCHMASTER PLUS 6 10 1/4 1790 132,000 0 ns. 15/8 x 131/4 x 121/2 $25,000
(MT-6 PLUS)
COMMAND CONSOLE 6 9 1/4 1110 84,000 0 ns. 2 x 131/2 x 121/2 $15,000
(CCI 6)
COMMAND CONSOLE PLUS 6 9 1/4 1450 108,000 0 ns. 2 x 131/2 x 121/2 $15,000
(CCI 6 PLUS)
COMMAND CONSOLE COMPACT 4 8 1/1 900 72,000 0 ns. 2 x 101/2 x 141/2 $5,000
(CCC 4)
POWER CENTER (PC 5) 5 6 1/5 65 6,500 <1 ns. 21/8 x 121/8 x 13 -
(PC 5)
ALL MODELS
Rated Input Voltage: 120V AC, 50 or 60 Hz
Rated Current and Load Handling: 15 amps maximum (1800) watts, 15 amps maximum per receptacle
Circuit Breaker: 15-amp resettable
Exceeds IEEE 587 category A & B specifications.
* All line cords are 3-conductor grounded.
** High-voltage spike protection works between hot to neutral, hot to ground and neutral to ground (except PC5: hot to neutral).
TELEPHONE LINE SPECIFICATIONS (PLUS MODELS ONLY)
Clamping Voltage: 260V peak +/- 10%
Response Time: <1 picosecond
Peak Transient Input Voltage: 6 Kv, 10 microseconds
Input/Output Connectors: two female "RJ" style modular jacks (phone cable included);
2-wire, single-line protection