Input cord length 6 ft., 14 gauge
Recommended
Electrical Service
15A 120V
BATTERY
Full load runtime 3 minutes (700VA)
Half load runtime 11 minutes (350VA)
DC system voltage 12V DC
Typical battery
lifespan
3-6 years, depending on usage
Battery recharge rate 2-4 hours to 90%
Replacement
Battery Cartridge
RBC51
LEDS ALARMS & SWITCHES
Front panel LEDs 3 front panel LEDs indicate line power status, battery power status and battery low/replace status
Alarms Audible alarm with 15-second delay sounds to indicate loss of utility power. Alarm can be silenced by pressing front
panel alarm cancel button. Once silenced, alarm will re-sound when approximately 2 minutes runtime remain.
Switches Includes 2 front panel switchesâone main on/off power switch and one dual function "alarm cancel" / "self test" button
SURGE / NOISE SUPPRESSION
AC surge
suppression
510 joules
AC suppression
response time
Instantaneous
Dataline suppression Tel/DSL/Ethernet
EMI / RFI AC noise
suppression
Yes
PHYSICAL
Shipping weight (lbs) 21
Shipping weight (kg) 9.5
Shipping
Dimensions
(HWD/in)
14 x 8.5 x 10.5
Shipping
Dimensions
(HWD/cm)
35.56 x 21.6 x 26.7
Unit weight (lbs) 19
Unit weight (kg) 8.6
Unit Dimensions
(HWD/in)
10.75 x 5.25 x 7.25
Unit Dimensions
(HWD/cm)
27.3 x 13.3 x 18.4
Material of
construction
PVC
Form factors
supported
Tower
Cooling method Convection
Battery Access Battery access door allows user replacement of UPS batteries. Hot-swappable battery replacement supported.
ENVIRONMENTAL
Relative Humidity 0 to 95%, non-condensing
Storage Temperature +5 to +122 degrees Fahrenheit