Tripp Lite OMNI300NAFTA Power Supply User Manual


 
Overvoltage
correction
Input voltages between 128-147VAC are reduced by 12%
Direct pass through Input voltages between 108-127VAC are passed on to connected equipment unchanged
Brownout correction Input voltages between 93-107VAC are boosted by 14%
Severe brownout
correction
Input voltages between 75-92VAC are boosted by 30%
LEDS ALARMS & SWITCHES
Front panel LEDs 4 front panel LEDs indicate line power status, battery power status, battery low/replace status and voltage regulation
operation
Alarms Audible alarm with 15-sec. delay sounds to indicate loss of utility power. Alarm can be silenced by pressing front panel
alarm cancel button. Once silenced, alarm will re-sound when approximately 2 min. runtime remain.
Switches Includes 2 front panel switches - one main on/off power switch and one dual function alarm cancel/self test button
SURGE / NOISE SUPPRESSION
AC surge suppression 480 joules
AC suppression
response time
Instantaneous
Dataline suppression Tel/DSL
EMI / RFI AC noise
suppression
Yes
PHYSICAL
Shipping weight (lbs) 15
Shipping weight (kg) 6.8
Shipping Dimensions
(HWD/in)
12.25 x 10 x 8.5
Shipping Dimensions
(HWD/cm)
31.1 x 25.4 x 21.6
Unit weight (lbs) 13.5
Unit weight (kg) 6.1
Unit Dimensions
(HWD/in)
8.5 x 5 x 6.5
Unit Dimensions
(HWD/cm)
21.6 x 12.7 x 16.5
Material of
construction
PVC
Form factors
supported
Tower
Cooling method Convection
Battery Access Battery access door allows user replacement of UPS batteries
ENVIRONMENTAL
Relative Humidity 0 to 95%, non-condensing
Storage Temperature +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Operating
Temperature
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
COMMUNICATIONS
Network monitoring
port
USB (HID)
Software and cabling
included
USB cabling included; PowerAlert Software available for free download at www.tripplite.com