Supports a half load of 700VA for 24 minutes
Automatic Voltage Regulation (AVR) circuits correct brownouts as low as 75 and overvoltages as high as 147 volts back to normal 120 volt
levels without using battery power
Upright tower configuration uses only 66 square inches of floor or desktop space
Includes 6 battery supported outlets, 6 foot AC line cord (all NEMA 5-15)
USB port enables safe unattended shutdown without data loss during extended power failures, includes USB cable
USB port supports messaging of UPS and line power status, including on-battery, low-battery, power-restored, AC line voltage, DC battery
voltage and battery capacity
USB interface supports timed inverter shutoff after unattended shutdown, activate self-test and 10 second reboot of connected equipment
PowerAlert UPS monitoring software available via free download from www.tripplite.com
Supports Tripp Lite's WatchDog software application to restore unresponsive programs by automatically restarting them and rebooting
completely locked computers by automatically switching UPS power off and back on again
Built-in audible alarm and 5 front panel LEDs indicate status of line power, battery power, battery low/replace, voltage regulation and
overload status
1400VA/940 watt power handling ability supports multiple entry-level PCs, network workstations, point-of-sale terminals, small to medium
business phone systems, audio/video equipment stations and heavily configured home theater systems
Supports hot-swap battery replacement via built-in battery access panel
Compatible with 120V/60Hz applications for USA, Canada, Mexico and more
2 year manufacturers warranty
$200,000 connected equipment insurance (USA & Canada only)
Specifications
SYSTEM OVERVIEW
Voltage compatibility 120V AC
Frequency
compatibility
60Hz
OUTPUT
Output VA 1400
Output watts 940
Output nominal
voltage
120V AC
Output voltage
regulation
LINE MODE: Sine wave line voltage 120V (-18% / +8%)
BATTERY MODE: PWM sine wave output 115V +/-5%
Output frequency
regulation
LINE MODE: Passes line frequency of 60Hz +/-10%
BATTERY MODE: Inverter output regulated to 60Hz +/-0.5Hz
Outlet quantity / type 6 NEMA 5-15R
INPUT
Maximum input amps 9.2A / 1030 watts
Input connection type NEMA 5-15P
Input cord length 6 ft., 16 gauge
Recommended
Electrical Service
15A 120V
BATTERY
Full load runtime 8 minutes (1400VA)
Half load runtime 24 minutes (700VA)
DC system voltage 36 VDC
Typical battery
lifespan
3-6 years, depending on usage
Battery recharge rate 2-4 hours to 90%
Replacement Battery
Cartridge
RBC53
VOLTAGE REGULATION