Tripp Lite SMART750RM1U Power Supply User Manual


 
Network interfaces support simultaneous communications via USB, DB9 serial and SNMPWEBCARD slot
Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus
any number of additional servers over IP
Communications ports support on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge
current, battery capacity, internal UPS temperature, AC line frequency, timed inverter shutoff, activate self-test and load bank output power
control
Built in Emergency Power Off (EPO) interface with cable
Sine wave output in AC and battery modes
Half load runtime of 24 minutes (375VA/225 watts)/Full load runtime of 7 minutes (750VA/450 watts)
Includes 6 NEMA 5-15R output receptacles arranged in 2 switchable single-outlet load banks
Integrated 2 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual devices
3 stage metered LEDs offer current monitoring and battery charge level
Mains power and voltage regulation LEDs offer at-a-glance power status information
Front panel switches support self-test and alarm cancel functions
UPS ships fully assembled in full compliance with DOT regulations, no time consuming connection of internal batteries by user required
UL (USA), cUL (Canada), NOM (Mexico), FCC Class A (Emissions) listed
2 year manufacturer's product warranty, $250,000 Ultimate Lifetime Insurance
Specifications
SYSTEM OVERVIEW
Voltage compatibility 120 VAC
Frequency
compatibility
60 Hz
OUTPUT
Output VA 750
Output watts 450
Output nominal
voltage
120V AC
Output voltage
regulation
LINE MODE: Sine wave line voltage 120V (-21% +8%), BATTERY MODE: Sine wave output within 5% of 120VAC
Output frequency
regulation
LINE MODE: Passes line frequency of 60Hz +/-10% BATTERY MODE: Inverter output regulated to 60Hz +/-0.5Hz
Outlet quantity / type 6 NEMA 5-15R
Customized load
management
receptacles
Includes 2 single-outlet load banks that support load shedding and remote reboot on demand of locked network
devices. Controllable via PowerAlert software to switch off optional loads, like monitors, to increase available runtime for
servers and other critical devices.
Overload protection 15A input breaker
INPUT
Maximum input amps 7A
Input connection
type
NEMA 5-15P
Input cord length 10 ft., 14 gauge
Recommended
Electrical Service
15A 120V
BATTERY
Full load runtime 7 minutes (450 watts)
Half load runtime 24 minutes (225 watts)
DC system voltage 24 VDC
Typical battery
lifespan
3-6 years, depending on usage
Battery recharge rate 2-4 hours to 90%