Tripp Lite SMART750USB Power Supply User Manual


 
Replacement battery
cartridge (internal UPS
battery replacement)
RBC51
Battery Access Battery access door
Battery replacement
description
Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage regulation
description
Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 89
Undervoltage correction Input voltages between 89 and 104 are boosted by 14%
LEDS ALARMS & SWITCHES
LED Indicators 4 LEDs indicate line power, battery power, overload and battery low/replace status
Alarms Audible alarm indicates power-failure and low-battery conditions
Alarm cancel operation Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate
low-battery status
Switches 2 Switches control off/on power status and alarm-cancel/self-test operation
SURGE / NOISE SUPPRESSION
UPS AC suppression joule
rating
510 joules
UPS AC suppression
response time
Instantaneous
UPS Dataline suppression 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet
EMI / RFI AC noise
suppression
Yes
PHYSICAL
Installation form factors
supported with included
accessories
Tower
Installation form factors
supported with optional
accessories
Wallmount (UPSWM - tower mounting kit)
Primary form factor Tower
UPS / Power Module
dimensions in primary form
factor (height x width x
depth / inches)
10.8 x 5.2 x 7.5
UPS / Power Module
dimensions in primary form
factor (height x width x
depth / cm)
27.3 x 13.3 x 19
UPS / Power Module weight
(lbs)
20
UPS / Power Module weight
(kg)
9.1
UPS Shipping dimensions
(height x width x depth /
inches)
14 x 8.5 x 10.5