Tripp Lite I Power Supply User Manual


 
5
Other UPS Features
AC Receptacles
All receptacles provide your connected equipment with AC line
power during normal operation and protect your equipment
against damaging surges and line noise. In addition, battery-
supported receptacles (identified on the back of your UPS) will
supply battery power during blackouts and brownouts.
RJ11 Telephone Jacks
These jacks protect your equipment against telephone line
surges. Connecting your equipment to these jacks is optional.
Your UPS will still work properly without this connection.
DB9 Port (Available on select models)
The DB9 port connects your UPS to any workstation or server.
Use with Tripp Lite software and cabling to automatically save
open files and shut down equipment during a blackout. This port
sends contact-closure signals to indicate
line-fail and low-
battery status. It also receives a shut down signal from the
connected computer to conserve the UPS battery charge. Contact
Tripp Lite Customer Support for more information.
Battery Replacement Door (Available on select models)
Under normal conditions, the original battery in your UPS will
last several years. Battery replacement should be performed only
by qualified service personnel. Refer to Battery Warnings in
the Safety section on page 2.
Storage & Service
Storage
First turn your UPS OFF and disconnect its power cord from the wall outlet. Then
disconnect all equipment to avoid battery drain. If you plan to store your UPS for
an extended period of time, fully recharge the UPS batteries once every
three months by plugging the UPS into a live AC outlet, turning the Power
Switch ON and letting the UPS charge for 4-6 hours. If you leave your UPS
batteries discharged for an extended period of time, they will suffer a permanent
loss of capacity.
Service
If returning your UPS to Tripp Lite, please carefully pack the UPS using the
ORIGINAL PACKING MATERIAL that came with the unit. Enclose a letter
describing the symptoms of the problem. If the UPS is within the 2 year
warranty period, enclose a copy of your sales receipt.
9811193 Internet Office Owner's Manual.p65 8/10/99, 11:59 AM5