SmartOnline 16kVA On-Line Double-Conversion UPS, N+1, 12U Rack/Tower, 200-240V L6-20R L6-30R outlets
Highlights
16kVA / 16,000VA / 14,400W on-line double-conversion UPS, 0.9 power factor
200/208/220/230/240V 50/60Hz output, Economy mode option
Hot-swap power & battery modules, N+1 fault tolerance at loads up to 8kVA
USB, RS232, EPO ports, Support for SNMP/WEB & other card options
Front panel LEDs with detailed LCD monitoring and control screen
Expandable runtime with optional external battery packs
Hardwire input (3 wire), L6-20R and L6-30R outlets
Description
Tripp Lite SU16KRT8 16,000VA / 16kVA / 14,400 watt online, double-conversion UPS system offers complete power protection for critical server,
network and telecommunications equipment in a 12U rack/tower configuration. This system delivers complete N+1 redundancy when used at loads
up to 8kVA, and non-redundant operation at loads between 8 and 16kVA. Fault-tolerant auto-bypass prevents unexpected service interruptions
during UPS overload or internal fault conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major
UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement
options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations.
Package Includes
Two SU8000RT3UPM UPS power modules
Two BP240V10RT3U battery packs
SUPDMB20K8 Parallel PDU with Bypass switch
4-post rackmount installation rails
PowerAlert software and cabling
Features
Tripp Lite SU16KRT8 16kVA, 16,000VA / 14,400 watt on-line, double-conversion UPS system in 12U total rack/tower configuration
Unique configuration offers 16kVA non-redundant operation and automatic N+1 redundancy at load levels of 8kVA and under
Included Parallel PDU with manual bypass switch enables hot-swap replacement of power modules at any supported load level
Hardwire input; 8 L6-20R and 2 L6-30R outlets
Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominal
Supports 50/60Hz operation for worldwide frequency compatibility
Expandable runtime with optional external battery packs
Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
Battery independent restart
Highly efficient economy mode option
Optional SNMPWEBCARD, RELAYIOCARD and RELAYIOMINI interface modules available (RELAYIOMINI requires removal of USB
interface module)
HID-compliant USB interface
Includes Free PowerAlert monitoring software; PowerAlert LOCAL, PowerAlert NSA and PowerAlert NMS for monitoring up to 250
SNMP-enabled UPS, PDU and other networking devices
Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (4 required)
Optional 2-9USTAND supports upright tower placement (2 required)
Supports Emergency Power Off (EPO) via built-in interface