PHYSICAL
Size 86 x 86 x 22mm (3.4” x 3.4” x 0.87”)
Weight 222.7g (7.9oz) with connectors
Housing Flame retardant polycarbonate
containing fully encapsulated
electronics.
Colour Dark Grey
Power
- Voltage 9 – 15Vdc
- Current
Consumption 140mA (passive), 250mA (peak)
Environmental
- Temperature -10º to 50ºC (14º to 122ºF)
- Humidity 95% non condensing
LED Indicators Three high intensity LED indicators red,
amber and green
LCD Indicators Two line by 16 character supertwist LCD
with backlight
Keypad 12 character, standard layout, tactile
response keypad.
FUNCTIONALITY
Inputs Four analog inputs (Transguard protected)
(General purpose use)
Configuration Operational parameters are downloaded
from associated online reader. Some
configuration setting can also be set using
the keypad.
COMMUNICATION INTERFACE
To IN Reader RS485 multidrop cable runs using copper
wire with maximum length of 1.2km
without repeater
- Connection 2 part screw terminals
PRODUCT CODES
InfoProx Exit IPX200 (125 kHz Proximity)
SPASS-IPX-200-B InfoProx Exit
SPASS-IPX-200-A InfoProx Exit (US Backplate)
InfoProx Exit IPX210 (MiFare CSN)
SPASS-IPX-210-B InfoProx Exit
SPASS-IPX-210-A InfoProx Exit (US Backplate)
CEM Systems Ltd Unit 4 Ravenhill Business Park Ravenhill Road Belfast BT6 8AW Northern Ireland
Tel: +44 (0)28 9045 6767 Fax: +44 (0)28 9045 4535 email: cem.sales@tycoint.com
www.cemsys.com
Door Control Unit Installation
The enclosure is designed to mount directly onto a standard
UK or European (French) electrical containment box (American
versions are provided with a compact adapter plate), meaning
that standard conduit and fittings may be used.
Card Technology
The InfoProx Exit reader (IPX200) uses 125 kHz proximity
technology under license from HID Corporation.
A 13.5 MHz technology (IPX210) option of the reader is
available enabling the InfoProx to read the unique ID of MiFare
smart cards (ISO14443A). The following cards are supported:
Type of Card Read Range (IPX200)
ISOProx® II Card 76mm (3.0in)
ProxCard™ Plus Card 38mm (1.5in)
ProxCard® II Card 76mm (3.0in)
ProxKey™ II Fob 25mm (1.0in)
Kantech 31bit Card 38mm (1.5in)
Type of Card Read Range (IPX210)
MiFare Card 30mm (1.18in)
Built-in Diagnostics
Allows testing of LED indicators, LCD display, read head, inputs,
relay, network communications, keypad and database size.
System Compatibility
The reader can be used with AC2000 or webEntry access control
systems.