Tyco webEntry II Network Card User Manual


 
TECHNICAL SPECIFICATIONS
PHYSICAL
Size 42 x 483 x 233mm (1U x 19” x 9.2”)
Weight 2.6Kg
Housing 19” rackmounted steel enclosure
Colour Beige
Power
- Voltage Mains power adapter 100-240Vac
(supplied)
Output voltage 12Vdc @ 2.0A
- Current
Consumption 300mA
- Backup Battery Internal Lithium Ion battery giving a
minimum of three hours backup time.
Power fail reported to system internally.
Environmental
- Temperature -10º to 50ºC (14º to 122ºF)
- Humidity 95% non condensing
LED Indicators Online/Offline, Ethernet connection,
Activity/Status, Power and Heartbeat
FUNCTIONALITY
Inputs Two Fire Zone Inputs
Dedicated Tamper Input
Two general purpose monitored inputs
Outputs Four volt-free changeover relays
Reader Capacity Up to 4 optically isolated RS485
multidrop reader networks controlling
up to 16 master readers each.
The combined maximum permissible
cable run is 1.2km per port.
Controller Memory 10MB of RAM
28KB Boot Loader ROM
Database memory Compact Flash Disk, 64MB
Storage of approximately 10,000
cards per controller, 500 with images.
Configuration/ Embedded Web Server allows full access
Management and all administration through a
standard web browser.
Browser Microsoft Internet Explorer 6 SP1
or higher
COMMUNICATION INTERFACE
To Card Readers Connected to webEntry II controller
using RJ45 connectors
To System Host Ethernet 10/100 Base T
Others Local RS232 serial port for controller
diagnostics/ configuration and
control of external equipment.
CONNECTION OPTIONS
CEM Systems Ltd Unit 4 Ravenhill Business Park Ravenhill Road Belfast BT6 8AW Northern Ireland
Tel: +44 (0)28 9045 6767 Fax: +44 (0)28 9045 4535 email: cem.sales@tycoint.com
www.cemsys.com
Onboard Database
The webEntry II Controller supports its own database of up
to 10,000 card records. The records include card numbers,
access level and time zone details. The database allows the
controller to validate card requests from readers.
Rack Mounted Enclosure
The webEntry II Controller comes mounted in a sturdy 19-
inch 1U rack-mounted enclosure providing easy integration
into existing server locations. The webEntry II Controller
can also be wall mounted with adjustment of the supplied
brackets.
Power Failure Capability
The webEntry II Controller has its own internal UPS, giving a
minimum of three hours normal usage in the event of mains
power failure, thus keeping potential downtime to
a minimum.
System Expansion
The webEntry II Controller can readily be upgraded to form
part of a fully scaleable AC2000 access control solution for
medium and large sites. All existing wiring and readers can
remain in place eliminating the need for new hardware.
Reader Networks
The reader networks connect to four RS485 serial ports on
the webEntry II Controller, using CAT 5 cabling. Each port
is distributed over four individual RJ45 cable connections
providing ease of installation and reducing the time
required to identify a faulty reader (see connection option
diagram below).
PRODUCT HIGHLIGHTS
CEM/B/016 Rev B
Product specifications and availability is subject to change without notice. Certain product names mentioned herein may be trade names
and/or registered trademarks of their companies.
Star
(up to 4 devices
per port)
Daisy Chain
(up to 16 devices
per port)
Combination
(up to 16 devices
per port)
Exit