VBrick Systems VB4000 Network Hardware User Manual


 
MPEG-2 Configuration
VBrick MPEG-2 Appliance Admin Guide 47
Configuration: System > Security
22 The 2.5 volts power supply failure has cleared.
23 There is a Real Time Clock battery failure.
24 The unit has been configured to transmit and/or receive video streams beyond
its capability.
25 Signifies the overloaded unit is recovered to normal.
26 A component on the main board failed Power On Self Test (POST).
27 The encoder card in Slot1 failed Power On Self Test (POST).
28 The encoder card in Slot1 failed Power On Self Test (POST).
Note If you disable Telnet, FTP, IWS, and SNMP, the only way to manage (and re-enable)
these parameters is to connect a PC to the VBrick with a serial cable and use the
Command Line Interface (CLI). You should never disable all the network management
interfaces if you are using COM2 for serial passthrough.
External Telnet
Server
Default = Enabled. Disabled will prevent Telnet sessions to the
server.
External FTP Server Default = Enabled. Disabled will prevent FTP sessions to the
server including downloading to the VBrick. Note that this feature
must be enabled to upgrade the appliance firmware using
VBDownload.
External IWS Default = Enabled. Disabled will prevent you from managing the
VBrick from a web browser using the IWS application.
Number Event Description