Verilux 41TDM Network Router User Manual


 
Configuration
EXIT
Press this button on the last char-
acter to enter the value and return
to the previous screen.
SCROLL
Press this button to increment the
characters (a–z, A–Z, 0–9, spe-
cial characters).
SELECT
Press this button to accept the cur-
rent value and move the cursor
right.
Indicators
TDM
This amber indicator is On when
the unit is configured for TDM
(Time Division Multiplexer)
mode.
TEST
This amber indicator is On when
the unit transmits loop code, un-
loop code, the 511 BERT pattern,
or when the unit is placed in a loop
mode such as line, data, V.54, etc.
ALARM
This red indicator is On when the
unit is in an active alarm condition.
POWER
This green indicator is On when
power is applied to the unit.
127 Jetplex Circle
Madison, Alabama 35758
(800) 837-4546
www.verilink.com
FAX-On-Demand
(800) 957-5465
Technical Assistance Center
(800) 285-2755
41TDM Menutree
Main Menu Network Configuration Mode: DDS-I, TXP-I, TXP-II, DDS-II
Rate: 56 K and 56 K
Timing: Network and Internal
Circuit Assurance: Off and On
Antistreaming Timer: ---, 10 seconds, 30 seconds, 60 seconds
Alarm Thresholds: FDL, OOS, OOF, LOS, ART
DTE Configuration Mode: TDM and STD
Port A Format: Sync and Async
Port B Rate: 2.4, 4.8, 9.6, 19.2, 31.2, 38.4, 52, 56, 57.6, 60, 64 kbps
Interface: RS-232, V.35, EIA-530
DSR: Force T and Test>Off
DCD: Force T, Far RTS, Idle>Off
RTS: Force On and Normal
RTS/CTS Delay: Normal and Long
DTR Alarm: Dis and En
V54 Loop: Dis and En
LL Detect: Dis and En
RL Detect: Dis and En
SNMP Configuration Unit IP Addr*
Router IP Addr*
Subnet Mask*
Fltr 1– 6 Addr*
SETs: Enable and Disable
Read Community*
Write Community*
Sys Contact*
Sys Name*
Sys Location*
Reset LAN: No and Yes
Diagnostics Loop Mode: Uni and Bi
BERT Function BERT: On and Off
Reset: No and Yes
SynLos (display only)
ErrSec (display only)
BitErr (display only)
Time: HH:MM:SS (display only)
Sync No Test (display only)
In Sync (display only)
Local Loop: Off and On
Far V.54 Loop: Off and On
V.54 Loop: Off and On
DTE-A Loop: Off and On
DTE-B Loop Off and On
Utilities Save Configuration: No and Yes
SUPV: 1.2 K, 2.4 K, 9.6 K, 19.2 K
SLIP: 1.2 K, 2.4 K, 9.6 K, 19.2 K
IP Port: SLIP
Date: MM/DD/YY
Time: HH:MM:SS
Contrast: 0–15
Status Displays Status: FDL, LOS, OOS, OOF, Idle, Test
A: RS, CS, CD, TR, SR
B:
* An underscore appears
under the character to
be entered or modified.